摘要 操动机构故障是高压断路器的主要故障之一。通过对机构的核心元件——分合闸线圈电磁脱扣器与储能电机进行建模,对分-合闸脱扣器和储能电机电流变化进行数学上的解释,并将预期特征与实际特征之差作为新的故障特征,减少了特征大小与外部因素之间的关系。经过仿真与实测样本波形对比,该模型能够有效解释和预测高压断路器中分合闸电磁铁与储能电机的电流波形,为实现精准的故障分类提供了良好的数据预处理基础。 The operating mechanism failure is one of the main reasons for the fault of the high-voltage circuit breaker.By modelling the core components of the mechanism,the electromagnetic trip of opening and closing coils and the energy storage motor,the current changes of the opening and closing release and the energy storage motor are explained mathematically,and the difference between the expected feature and the actual feature is taken as the new fault feature,which can reduce the relationship between the feature size and external factors.By comparing the simulated and measured sample waveforms,the model can effectively explain and predict the current waveforms of the opening and closing electromagnets and energy storage motors in the high-voltage circuit breakers,which provides a good data preprocessing basis for accurate fault classification.
作者 胡光福 沈忠威 陈晨 历小润 李电 罗国力 HU Guangfu;SHEN Zhongwei;CHEN Chen;LI Xiaorun;LI Dian;LUO Guoli(Ningbo Shunli High Voltage Switch Technology Co.,Ltd.,Yuyao Zhejiang 315400,China;Cooper(Ningbo)Electric Co.,Ltd.,Ningbo Zhejiang 315300,China;Zhejiang University,Hangzhou 310027,China;State Grid Shaoxing Power Supply Company,Shaoxing Zhejiang 312000,China)
出处 《浙江电力》 2020年第1期97-102,共6页 Zhejiang Electric Power
关键词 模型法 断路器 电磁脱扣器 储能电机 model method circuit breaker electromagnetic trip energy storage motor
  • 相关文献

参考文献14

二级参考文献138

共引文献390

同被引文献53

引证文献5

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部