文章对低电压台区存在的主要问题及其影响因素进行了分析,并提出低电压台区电压质量的优化措施,如负荷换相、增大线径、负荷转移、变压器增容、补偿电压等。
In this paper,the main problems and their influencing factors in the low voltage substation area are analyzed.The optimization measures of voltage quality in low voltage substation area are put forward.The measures include load commutation,line diameter increase,load transfer,transformer capacity increase,offset voltage,etc.
作者
陆伟明
吕梦丽
LU Weiming;LV Mengli(Zhanjiang Power Supply Bureau of Guangdong Power Grid Co.,Ltd.,Zhanjiang 524000,China)
出处
《电工技术》
2019年第24期60-61,64,共3页
Electric Engineering
关键词
低电压
负荷换相
增大线径
负荷转移
补偿电压
low voltage
load commutation
line diameter increase
load transfer
offset voltage