期刊文献+

污泥直喷入窑对水泥窑的影响 被引量:4

Effect of direct injection sludge into cement kiln
下载PDF
导出
摘要 以某水泥厂湿污泥直喷入窑工艺为研究对象,通过对污泥理化特性的分析,以水分为依据,计算了湿污泥直喷入窑的处置量限值、热耗,并以实际工业试验验证了湿污泥直喷入窑对水泥窑能耗及烟气中氮氧化物和二噁英减排的影响。结果表明:污泥含水率是影响水泥窑况的主要因素。含水率为80%的污泥,直接泵送进入水泥窑的量一般控制在生料量3%~5%为宜;理论上,处置每吨污泥净吸热为:4722078.13 kJ;将污泥直喷入窑,氮氧化物削减了30%以上,二噁英削减了60%以上。 The process of wet sludge direct injection into cement kiln of a cement plant was studied, and the limit amount and heat consumption of sludge were calculated based on its moisture content from physical and chemical properties analysis. The effect of direct injection sludge into cement kiln on energy consumption, nitrogen oxide and dioxin emissions in flue gas were verified in actual industry. The results showed that the sludge moisture content was the main factor affecting cement kiln conditions while direct injecting. Generally, it is appropriate to control sludge amount of 3% to 5% of raw material when direct injection sludge with 80% moisture content. In theory, the net heat absorption per ton of sludge during co-processing was 4 722 078.13 kJ. Nitrogen oxides reduced by more than 30% and dioxins reduced by more than 60% after direct injection sludge into the cement kiln.
作者 李春萍 郭瑞 LI Chunping
出处 《水泥》 CAS 2020年第1期17-20,共4页 Cement
关键词 污泥 水分 氮氧化物 二噁英 sludge moisture NO_x dioxin
  • 相关文献

参考文献7

二级参考文献38

共引文献93

同被引文献17

引证文献4

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部