期刊文献+

The impact of UV treatment on microbial control and DBPs formation in full-scale drinking water systems in northern China 被引量:2

The impact of UV treatment on microbial control and DBPs formation in full-scale drinking water systems in northern China
原文传递
导出
摘要 To manage potential microbial risks and meet increasingly strict drinking water health standards,UV treatment has attracted increasing attention for use in drinking water systems in China.However,the effects of UV treatment on microbial control and disinfection byproducts(DBPs)formation in real municipal drinking water systems are poorly understood.Here,we collected water samples from three real drinking water systems in Beijing and Tianjin to investigate the impacts of UV treatment on microbial control and DBP formation.We employed heterotrophic plate count(HPC),flow cytometry(FCM),quantitative PCR analysis,and high-throughput sequencing to measure microorganisms in the samples.Different trends were observed between HPC and total cell count(measured by FCM),indicating that a single indicator could not reflect the real degree of biological re-growth in drinking water distribution systems(DWDSs).A significant increase in the 16S rRNA gene concentration was observed when the UV system was stopped.Besides,the bacterial community composition was similar at the phylum level but differed markedly at the genera level among the three DWDSs.Some chlorine-resistant bacteria,including potential pathogens(e.g.,Acinetobacter)showed a high relative abundance when the UV system was turned off.It can be concluded that UV treatment can mitigate microbial re-growth to some extent.Finally,UV treatment had a limited influence on the formation of DBPs,including trihalomethanes,haloacetic acids,and nitrogenated DBPs.The findings of this study may help to understand the performance of UV treatment in real drinking water systems. To manage potential microbial risks and meet increasingly strict drinking water health standards,UV treatment has attracted increasing attention for use in drinking water systems in China.However,the effects of UV treatment on microbial control and disinfection byproducts(DBPs) formation in real municipal drinking water systems are poorly understood.Here,we collected water samples from three real drinking water systems in Beijing and Tianjin to investigate the impacts of UV treatment on microbial control and DBP formation.We employed heterotrophic plate count(HPC),flow cytometry(FCM),quantitative PCR analysis,and high-throughput sequencing to measure microorganisms in the samples.Different trends were observed between HPC and total cell count(measured by FCM),indicating that a single indicator could not reflect the real degree of biological re-growth in drinking water distribution systems(DWDSs).A significant increase in the 16 S rRNA gene concentration was observed when the UV system was stopped.Besides,the bacterial community composition was similar at the phylum level but differed markedly at the genera level among the three DWDSs.Some chlorine-resistant bacteria,including potential pathogens(e.g.,Acinetobacter) showed a high relative abundance when the UV system was turned off.It can be concluded that UV treatment can mitigate microbial re-growth to some extent.Finally,UV treatment had a limited influence on the formation of DBPs,including trihalomethanes,haloacetic acids,and nitrogenated DBPs.The findings of this study may help to understand the performance of UV treatment in real drinking water systems.
机构地区 School of Environment
出处 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2020年第1期398-410,共13页 环境科学学报(英文版)
基金 supported by the National Natural Science Foundation of China(Nos.51778323,51761125013 and51290284) the National Science and Technology Major Project of China(Nos.2012ZX07404-002,2017ZX07108-003 and 2017ZX07502-003)
关键词 UV treatment Bacterial community Disinfection by-products(DBPs) Multi-barrier disinfection Municipal drinking water systems UV treatment Bacterial community Disinfection by-products(DBPs) Multi-barrier disinfection Municipal drinking water systems
  • 相关文献

参考文献3

二级参考文献31

  • 1徐扬.保障北京城市供水水质关键技术的研究与应用[J].城镇供水,2005(6):11-15. 被引量:1
  • 2孙迎雪,田媛.微污染水源饮用水处理理论及工程应用[M].北京:化学工业出版社,2011. 被引量:4
  • 3Sarin P, Snoeyink V L, Bebee J, et al. Physico-chemical characteristics of corrosion scales in old iron pipes [J]. War. Res., 2001,35(12):2961-2969. 被引量:1
  • 4Husband P S, Boxall J B. Asset deterioration and discolouration in water distribution systems [J]. Wat. Res., 2011,45(1): 113-124. 被引量:1
  • 5Shi B Y, Taylor J S. Iron and copper release in drinking-water distribution systems [J]. J. Environmental Health, 2007,70(2):29-36. 被引量:1
  • 6Liu G, Bakker G L, Li S, et al. Pyrosequencing reveals bacterial communities in unehlorinated drinking water distribution system: an integral study of bulk water, suspended solids, loose deposits, and pipe walt biofilm [J]. Environ. Sci. Technol., 2014,48(10):5467-5476. 被引量:1
  • 7Liao X, Chen C, Wang Z, et al. Bacterial community change through drinking water treatment processes [J]. International Joumal of Environmental Science and Technology, 2014:1-8. DOI 10.1007/s13762-014-0540-0. 被引量:1
  • 8Prest E I, E1-Chakhtoura J, Hammes F, et al. Combining flow cytometry and 16S rRNA gene pyrosequancing: A promising approach for drinking water monitoring and characterization [J]. Wat. Rcse., 2014,63(10): 179-189. 被引量:1
  • 9Lane D J. 16S/23S rRNA sequencing. In Nuecleic acid techniques in bacterial systematics eds. Staekebrandt, E. and Goodfellow, M [M]. Chester, England: John Wiley and Sons., 1991,l 15-147. 被引量:1
  • 10Caporaso J G, Kuczynski J, Stombaugh J, et al. QIIME allows analysis of high-throughput community sequencing data [J]. Nature Methods, 2010,7(5):335-336. 被引量:1

共引文献26

同被引文献7

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部