摘要 心冲击图(Ballistocardiography,BCG)记录了人体心脏做机械运动时对外界的作用力信号,不仅能反应心脏节律,还能作为评估心脏血流动力学参数变化的有效依据。但BCG信号的采集过程中影响因素较多,这些严重地影响着信号形态特征,进而导致对其进行血流动力学分析得不准确。因此,该文采用聚偏氟乙烯压电薄膜传感器,设计并实现了能够有效抑制外界干扰、具有高信噪比的BCG信号采集系统。基于该系统研究了传感器位置、床垫硬度、躺卧姿势对采集系统稳定性的影响,并分析了在呼吸暂停情况下采集系统的检测性能。结果表明,在卧姿采集BCG信号时,应选择硬质床垫(如木板床),并将传感器摆在心脏正下方的位置,使受试者保持平躺姿势。满足上述条件时,所采集的BCG信号波形最佳,H、J、K波波形明显,且具有较强的节律性,有利于提高后续血流动力学分析的精度。 Ballistocardiography(BCG)is a technique that records the force signal caused by the ejection of blood into the arteries with each heartbeat.BCG signal can be acquired non-invasively by using polyvinylidene fluoride(PVDF)sensors integrated in a mattress or chair.In addition to being able to show cardiac rhythms,BCG signals can also be used for assessing cardiac hemodynamic changes.However,body movements,sensor displacement,etc.can easily influence the morphological characteristics of BCG signal,which makes its hemodynamic analysis difficult and even impossible.In this paper,we developed a BCG signal acquisition system using PVDF sensor.The proposed system can effectively suppress external electromagnetic interference and result in high signal-to-noise ratio.Specifically,we systematically investigated the effects of sensor position,mattress hardness and user’s posture on the stability of the BCG acquisition system,and analyzed the detection performance under apnea and the difference in gender characteristics of BCG signals.The evaluation results demonstrate that when collecting BCG signals in a lying position,it is better to use a hard mattress(such as a wooden bed)and place the sensor directly below the hear.When the above conditions are met,the collected BCG signals waveform is the optimal;the H,J,and K waves are significant and have a strong rhythm,which is conducive to improving the accuracy of hemodynamic analysis.
作者 王璐 王仲怡 吴子悦 徐敬傲 蒋芳芳 徐礼胜 于滨 WANG Lu;WANG Zhongyi;WU Ziyue;XU Jing'ao;JIANG Fangfang;XU Lisheng;YU Bin(School of Computer Science and Engineering,Northeastern University,Shenyang 110819,China;College of Medicine and Biological Information Engineerings Northeastern University,Shenyang 110819,China;Neusoft Research of Intelligent Healthcare Technology,Co.Ltd.,Shenyang 110167,China;Industrial Design Center,Eindhoven University of TechnologyEindhoven 5600,the Netherlands)
出处 《集成技术》 2020年第1期36-44,共9页 Journal of Integration Technology
基金 国家自然科学基金项目(61773110、61801104) 辽宁省自然科学基金项目(20170540312) 中央高校基本科研业务费项目(N181604006)
关键词 心冲击信号 聚偏氟乙烯传感器 非接触体征监护 呼吸暂停 ballistocardiography polyvinylidene fluoride sensor non-contact monitoring apnea
  • 相关文献

参考文献4

二级参考文献46

共引文献3531

同被引文献12

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部