基于优化赋权-云模型的地铁站消防安全评价 被引量:6

Fire safety evaluation of subway station based on combined weig-cloud model
下载PDF
导出
摘要 为高效地评定地铁车站消防安全状态,从四个维度构建地铁车站消防安全评价指标体系。通过改进的CM-AHP法与因子分析方法对指标赋权,并基于最小二乘法组合优化。根据修正后的云数字特征生成云模型,进而集成浮动综合等级模型。结合指标的等级隶属度与组合权重获得综合评价云模型,通过云图直观展示车站消防安全状态对各综合等级云的依赖程度和发展趋势。 In order to effectively evaluate the fire safety status of metro stations,the fire safety evaluation index system of subway stations is constructed from four dimensions.The weights of indexes are determined by the improved CM-AHP and factor analysis,and the combination optimization is based on the least square method.The cloud model is generated according to the modified digital characteristics,and then the floating comprehensive level model is integrated.The comprehensive evaluation cloud model is obtained by combining the grade membership degree and combination weight of the indexes.Through the cloud map,the degree of dependency on the comprehensive level cloud and the development trend of the fire safety state can be seen intuitively.
作者 黄莺 王轲 雷俊 HUANG Ying;WANG Ke;LEI Jun(School of Civil Engineering,Xi'an University of Architecture&Technology,Shaanxi Xi'an 710055,China;National Experimental Teaching Center for Civil Engineering Virtual Simulation(XAUAT),Shaanxi Xi'an 710055,China)
出处 《消防科学与技术》 CAS 北大核心 2020年第1期110-114,共5页 Fire Science and Technology
基金 国家自然科学基金资助项目(51308448) 西安市建设科技计划项目(SJW2017–02)
关键词 地铁车站 消防安全 CM-AHP 因子分析 浮动云模型 metro station fire safety CM-AHP factor analysis cloud model
  • 相关文献

参考文献11

二级参考文献114

共引文献117

同被引文献73

引证文献6

二级引证文献28