期刊文献+

双列运行机组增设外置式蒸汽冷却器方案对比分析及应用 被引量:1

Comparative Analysis and Application of Retrofit Schemes for a Biserial Power Unit by Adding External Steam Coolers
下载PDF
导出
摘要 以某电厂1000 MW超超临界火电机组为例,对增设外置式蒸汽冷却器的不同方案进行了性能对比分析,介绍了改造步骤并分析了改造效果。结果表明:随着负荷的降低,增设外置式蒸汽冷却器的节能效果更明显;该方案不增加管道沿程阻力、不排挤除氧器抽汽,同时可提高SCR脱硝系统入口烟温、降低汽轮机热耗率,具有安全性和节能性。 Taking the 1000 MW power unit as an example,a comparative analysis was conducted on the performance of different retrofit schemes for the unit by adding external steam coolers,with focus on the retrofit steps and effectiveness.Results show that with the reduction of unit load,the energy-saving effectiveness becomes more obvious by adding external steam coolers.The scheme proposed would not increase the flow resistance in the pipeline and push out the steam extraction of the deaerator,but may increase the inlet gas temperature of the SCR denitrification system and reduce the heat consumption of the steam turbine,resulting in high safety and energy-saving effects of the unit.
作者 朱晓磊 李剑宁 张胤 Zhu Xiaolei;Li Jianning;Zhang Yin(Shanghai Power Equipment Research Institute Co., Ltd., Shanghai 200240, China;Shanghai Shangdian-Caojing Power Generation Co., Ltd., Shanghai 201500, China)
出处 《发电设备》 2020年第1期60-65,共6页 Power Equipment
关键词 火电机组 外置式蒸汽冷却器 高压加热器 给水温度 过热度 煤耗 thermal power unit external steam cooler high-pressure heater feed water temperature degree of superheat coal consumption