期刊文献+

家用燃气热水器出水管路热损失研究

Study on Heat Loss of Water Pipeline of Domestic Gas Water Heater
下载PDF
导出
摘要 基于市场的反馈和人们对于生活体验需求的不断提升,用户家用燃气热水器管路末端水温过低的呼声,严重影响了用户的体验效果。通过实验模拟用户不同生活环境、用水环境及管路装修敷设环境,对热水器出水管路热损失进行了测试及数据处理。最终根据以上测试结果,为用户提供了一种可供参考的管路安装环境及合理的热水器设置温度。 Based on the feedback from the market and the continuous improvement of user’s demand for life experience, the voice that the water temperature at the end of the gas water heater pipeline is too low has seriously affected the user’s experience effect. Through the simulation of different living environment, water environment and pipeline decoration and laying environment, the heat loss of water heater outlet pipeline was tested and datum processing were carried out. Finally, according to the above test results, a kind of pipeline installation environment and reasonable water heater setting temperature are provided for users.
作者 孙娟 夏瑞丽 谢朝东 SUN Juan;XIA Ruili;XIE Chaodong(Ningbo Fotile Kitchen Ware Co.,Ltd.)
出处 《上海煤气》 2019年第6期23-27,共5页 Shanghai Gas
关键词 家用燃气热水器 管路热损失 用户环境模拟 domestic gas water heater pipeline heat loss user environment simulation