期刊文献+

三维动脉自旋标记脑灌注MRI在阿尔兹海默症患者脑部血流动力学评估中的应用价值分析 被引量:2

The Value of Three-dimensional Artery Spin-labeled Cerebral Perfusion MRI in Cerebral Hemodynamics Evaluation of Alzheimer’s Patients
下载PDF
导出
摘要 目的:探讨三维动脉自旋标记脑灌注MRI(three-dimension arterial spin labeling, 3D-ASL)在阿尔兹海默症患者脑部血流动力学评估中的应用价值。方法:研究对象选取我院2014年3月~2016年9月收治的38例阿尔兹海默症患者与同期与我院行健康体检的38例老年志愿者,分别设为观察组和对照组。对所有受试者均采用三维动脉自旋标记脑灌注MRI及MMSE、MOCA量表评测,比较观察组患者脑部血流明显减低区血流灌注情况以及各血流灌注减低区血流量值与MMSE、MOCA评分相关性。结果:观察组患者双侧颞叶、双侧楔前叶、双侧扣带回、左侧枕叶血流量值明显低于对照组,差异具有统计学意义(P<0.05);且这些脑区的脑血流量与MMSE、MOCA量表均呈显著正相关(r>0.60, P<0.05)。结论:三维动脉自旋标记脑灌注MRI能反映阿尔兹海默患者脑部血流动力学的改变,且与临床神经心理学量表相关性高,因此在探究阿尔兹海默症的病理学及病理生理学原理上具有重要应用价值。 Objective:To evaluate the value of three-dimensional arterial spin labeling(3 D-ASL) in cerebral hemodynamics assessment of patients with Alzheimer’s disease.Methods:Subjects were selected from 38 patients with Alzheimer’s disease in our hospital from March 2014 to September 2016 and 38 elderly volunteers who were in the same period with our hospital for physical examination. They were the observation group and the control group. All the subjects were treated with three-dimensional arterial spin labeling brain perfusion MRI and MMSE, MOCA scale, compared with the observation group of patients with brain blood flow was significantly reduced blood perfusion and blood flow reduction area blood flow values and MMSE, MOCA score correlation.Results:The blood flow values of bilateral temporal lobe, bilateral anterior wedge, bilateral cingulate gyrus and left occipital lobe were significantly lower in the observation group than in the control group, the differences were statically significant(P<0.05);and the cerebral blood flow in these brain regions was positively correlated with MMSE and MOCA(r>0.60, P<0.05).Conclusion:Three-dimensional arterial spin labeling of brain perfusion MRI can reflect Alzheimer’s brain changes in brain hemodynamics, and with the clinical neuropsychological scale correlation, so it has important application value in exploring the pathology and pathophysiology of Alzheimer’s disease.
作者 梁宏 Liang Hong(Department of Radiology,The First People's Hospital of Zhaoqing City,Zhaoqing,Guangdong 526060)
出处 《现代医用影像学》 2019年第11期2390-2393,共4页 Modern Medical Imageology
关键词 阿尔兹海默症 三维动脉自旋标记脑灌注MRI 血流动力学 MOCA量表 Alzheimer’s Disease Three-dimensional Artery Spin-labeled Cerebral Perfusion MRI Cerebral Hemodynamics MOCA
  • 相关文献

参考文献7

二级参考文献55

  • 1Liu TT,Brown GG.Measurement of cerebral perfusion with arterial spin labeling:Part 1.Methods[J].J Int Neuropsychol Soc, 2007,13(3):517-525. 被引量:1
  • 2Yang Y,Engehen W,Xu S,et al.Transit time, trailing time, and cerebral blood flow during brain activation:Measurement using multislice, pulsed spin-labeling perfusion imaging[J].Magn Reson Med,200(h 44(5):680-685. 被引量:1
  • 3Wang J,Alsop DC,Song HK,et aLArtefial transit time imaging with flow encoding arterial spin tagging (FEAST)IJ].Magn Re.son Med, 2003,50(3):599-607. 被引量:1
  • 4Qiu M,Paul Maguire R,Arom J,et al.Arterial transit time effects in pulsed arterial spin labeling CBF mapping:insight fi'om a PET and MR study in normal human subjects[J].Magn Reson Med,2010, 63(2):374-384. 被引量:1
  • 5Raichle ME,Martin WR,Herscovitch P,et al.Brain blood flow measured with intravenous H2(15)O.ll.Implementation and validation[J].J Nucl Med, 1983,24(9):790- 798. 被引量:1
  • 6Noguchi T,Yoshiura T,Hiwatashi A,et al.Perfusion imaging of brain tumors using arterial spin-labeling: correlation with histopathologic vascular density[J].AJNR Am J Neuroradiol, 2008,29(4) :688-693. 被引量:1
  • 7Chen Y,Wang DJJ,Detre JA.Comparison of arterial transit times estimated using arterial spin labeling[J].MAGMA,2012, 25(2):135-144. 被引量:1
  • 8Naganawa S,Kawai H,Fukatsu H,et al.High-speed imaging at 3 Tesla:a technical and clinical review with an emphasis on whole- brain 3D imang[J] .Magn Reson Med Sci,2004,3( 4 ) :177-187. 被引量:1
  • 9Dai W,Lopez OL,Camfichael OT,et al.Mild Cognitive Impairment and Alzheimer Disease: Patterns of Altered Cerebral Blood Flow at MR Imaging1[J].Radiology,2009,250(3):856-866. 被引量:1
  • 10Xu G,Rowley HA,Wu G,et al.Reliability andprecision of pseudocontinuous arterial spin labelingperfusion MRI on 3.0T and comparion with O-water PET in elderly subjects at risk for Alzheimei disease[J].NMR Biomed,2010,23:286-293. 被引量:1

共引文献34

同被引文献33

引证文献2

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部