期刊文献+

Low drift nuclear spin gyroscope with probe light intensity error suppression 被引量:4

Low drift nuclear spin gyroscope with probe light intensity error suppression
下载PDF
导出
摘要 A nuclear spin gyroscope based on an alkali-metal–noble-gas co-magnetometer operated in spin-exchange relaxationfree(SERF) regime is a promising atomic rotation sensor for its ultra-high fundamental sensitivity. However, the fluctuation of probe light intensity is one of the main technical error sources that limits the bias stability of the gyroscope. Here we propose a novel method to suppress the bias error induced by probe light intensity fluctuations. This method is based on the inherent magnetic field response characteristics of the gyroscope. By the application of a bias magnetic field, the gyroscope can be tuned to a working point where the output signal is insensitive to probe light intensity variation, referred to herein as ‘zero point’, thus the bias error induced by intensity fluctuations can be completely suppressed. The superiority of the method was verified on a K–Rb–21 Ne co-magnetometer, and a bias stability of approximately 0.01°/h was obtained. In addition, the method proposed here can remove the requirement of the closed-loop control of probe light intensity, thereby facilitating miniaturization of the gyroscope volume and improvement of reliability. A nuclear spin gyroscope based on an alkali-metal–noble-gas co-magnetometer operated in spin-exchange relaxationfree(SERF) regime is a promising atomic rotation sensor for its ultra-high fundamental sensitivity. However, the fluctuation of probe light intensity is one of the main technical error sources that limits the bias stability of the gyroscope. Here we propose a novel method to suppress the bias error induced by probe light intensity fluctuations. This method is based on the inherent magnetic field response characteristics of the gyroscope. By the application of a bias magnetic field, the gyroscope can be tuned to a working point where the output signal is insensitive to probe light intensity variation, referred to herein as ‘zero point’, thus the bias error induced by intensity fluctuations can be completely suppressed. The superiority of the method was verified on a K–Rb–21 Ne co-magnetometer, and a bias stability of approximately 0.01°/h was obtained. In addition, the method proposed here can remove the requirement of the closed-loop control of probe light intensity, thereby facilitating miniaturization of the gyroscope volume and improvement of reliability.
作者 Wenfeng Fan Wei Quan Feng Liu Lihong Duan Gang Liu 范文峰;全伟;刘峰;段利红;刘刚(School of Instrumentation and Optoelectronic Engineering,Beihang University,Beijing 100191,China;Beijing Advanced Innovation Center for Big Data-Based Precision Medicine,Beihang University,Beijing 100191,China;Beijing Academy of Quantum Information Sciences,Beijing 100193,China)
出处 《Chinese Physics B》 SCIE EI CAS CSCD 2019年第11期129-133,共5页 中国物理B(英文版)
基金 Project supported by the National Key Research and Development Program of China(Grant Nos.2016YFB0501600 and 2017YFB0503100) the National Natural Science Foundation of China(Grant Nos.61773043,61673041,and 61721091)
关键词 nuclear spin GYROSCOPE SPIN-EXCHANGE relaxation-free ERROR SUPPRESSION PROBE light intensity nuclear spin gyroscope spin-exchange relaxation-free error suppression probe light intensity
  • 相关文献

同被引文献7

引证文献4

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部