本文着重介绍利用西门子报文352-PZD6/6结合可编程控制器S7-1500和触摸屏TP1200来驱动S120变频器的详细应用方法,该应用通过TIA Portal和STARTER软件配置和编程来读取变频器的各项参数及控制电机的启停,在无需增加额外硬件配置的情况下满足用户监控S120变频器的需求。
The detailed application method of driving S120 inverter by use of Siemens message 352-PZD6/6 in combination with programmable controller S7-1500 and touch screen TP1200 has been mainly introduced in the text. The application reads each data of converter and controls the start-stop of motor by use of TIA Portal and STARTER software configuration and programming. The requirement of monitoring S120 inverter by the user has been realized without adding additional hardware configuration.
作者
沈盛阳
徐凯
郭星
SHEN Shengyang;XU Kai;GUO Xing(Jiangsu Yangli Group Co.,Ltd.,Yangzhou 225000,Jiangsu China)
出处
《锻压装备与制造技术》
2019年第4期66-69,46,共5页
China Metalforming Equipment & Manufacturing Technology
关键词
西门子报文
可编程控制器
触摸屏
变频器
Siemens message
Programmable controller
Touch screen
Frequency converter