期刊文献+

磁混凝/强化耦合生物膜工艺用于河道水质提升 被引量:12

Application of Magnetic Coagulation Sedimentation/Enhanced Hybrid Biofilm Reactor in River Water Quality Improvement
原文传递
导出
摘要 A河道黑臭水体河段长为3. 1 km,劣Ⅴ类水质,采用磁混凝沉淀/强化耦合生物膜(MagCS+EHBR)旁路处理工艺,处理水量为2×10^4m^3/d。近半年的调试及运行监测结果表明,出水指标优于《地表水环境质量标准》(GB 3838—2002)Ⅳ类标准,从而保障了下游考核断面水质达到Ⅴ类标准,运行成本为0. 19元/m^3。通过对工程项目实施的跟踪,取得第一手监测数据,可为黑臭水体治理及河道水质提升工程的应用研究提供科学资料。 The length of black and odorous water body in river A was 3. 1 km and the original water quality was inferior level V. The magnetic coagulation sedimentation( MagCS)/enhanced hybrid biofilm reactor( EHBR) was adopted for bypass treatment with daily water treatment capacity of 20 000 m^3. The commissioning and operation monitoring results in the past half year showed that the main effluent indexes of bypass treatment were superior to level Ⅳ criteria of Environmental Quality Standards for Surface Water( GB 3838-2002),which ensured that the down stream assessment section met levelⅤ standard. The operation cost was 0. 19 yuan/m^3. By tracking the implementation of the project,the first-hand monitoring data could be obtained, which could provide scientific information for the application research of black and odorous water treatment and river water quality improvement project.
作者 郁片红 YU Pian-hong(Shanghai Urban Construction Design & Research < Group > Co. Ltd., Shanghai 200125 ,China)
出处 《中国给水排水》 CAS CSCD 北大核心 2019年第18期83-87,共5页 China Water & Wastewater
关键词 黑臭水体 水质提升 磁混凝沉淀 强化耦合生物膜 black and odorous water body water quality improvement magnetic coagulation sedimentation( MagCS) enhanced hybrid biofilm reactor( EHBR)
  • 相关文献

参考文献5

二级参考文献31

共引文献57

同被引文献79

引证文献12

二级引证文献21

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部