对于采用电极锅炉蓄能的热网,在不同热负荷工况下,机组产生的供热量和电极锅炉产生的供热量总和不同,所以要考虑电极锅炉的装机容量问题。以某热电厂热网实际工况为例,对采用电极锅炉蓄能调峰方法的经济性进行了分析,通过几组不同负荷工况下计算结果的对比选择出最优的负荷工况,进而确定电极锅炉最佳装机容量,计算结果为确定电极锅炉的装机方案和解决热网调峰问题提供了依据。
For the heating network with the electrode boiler for energy storage, the sum of heating amount generated by the unit and that generated by the electrode boiler is different under different thermal load conditions, so the installation capacity of the electrode boiler should be considered.In this paper, the economy of the heat supply network in a thermal power plant under the actual loading condition with the electrode boiler for energy storage was analyzed.The optimal installed capacity of the electrode boiler were selected by comparing the results of several groups of different load conditions, and the calculation results would provide some reference to determine the electrode boiler installation scheme and improve the peak load regulation of the heat supply network.