期刊文献+

Effects of Trenched Film Hole Configurations on the Endwall Film Cooling and Suction Side Phantom Cooling 被引量:2

Effects of Trenched Film Hole Configurations on the Endwall Film Cooling and Suction Side Phantom Cooling
原文传递
导出
摘要 To maximize the turbine thermal efficiency, modern gas turbine’s inlet temperature is significantly augmented within the past few decades. To prolong the lifespan of gas turbines, many efficient cooling techniques have been proposed and applied in the endwall cooling schemes. However, conventional discrete film hole does not take effect at the leading edge nearby region. In this research, how the trenched film hole configurations affects the endwall cooling and phantom cooling characteristics were deeply studied by using a verified approach. Steady 3D Reynolds-averaged Navier-Stokes(RANS) governing equations together with the shear stress transport(SST) k-w turbulence model have been solved. Firstly, results indicate that trenched film holes greatly influence the cooling effectiveness at leading edge nearby region compared to normal case. Nevertheless, suction side phantom cooling is hardly influenced by the trenched film holes. Secondly, the case with a smaller trench width obtains higher endwall cooling effectiveness, particularly at upstream region. More importantly, the cases with W=3D achieve large cooling effectiveness at leading edge nearby region with little influence by trench depth. Additionally, majority of trenched film holes coolant flow is driven towards middle passage. Therefore, the suction side phantom cooling is unaffected by the trenched film holes. To maximize the turbine thermal efficiency, modern gas turbine’s inlet temperature is significantly augmented within the past few decades. To prolong the lifespan of gas turbines, many efficient cooling techniques have been proposed and applied in the endwall cooling schemes. However, conventional discrete film hole does not take effect at the leading edge nearby region. In this research, how the trenched film hole configurations affects the endwall cooling and phantom cooling characteristics were deeply studied by using a verified approach. Steady 3D Reynolds-averaged Navier-Stokes(RANS) governing equations together with the shear stress transport(SST) k-w turbulence model have been solved. Firstly, results indicate that trenched film holes greatly influence the cooling effectiveness at leading edge nearby region compared to normal case. Nevertheless, suction side phantom cooling is hardly influenced by the trenched film holes. Secondly, the case with a smaller trench width obtains higher endwall cooling effectiveness, particularly at upstream region. More importantly, the cases with W=3D achieve large cooling effectiveness at leading edge nearby region with little influence by trench depth. Additionally, majority of trenched film holes coolant flow is driven towards middle passage. Therefore, the suction side phantom cooling is unaffected by the trenched film holes.
出处 《Journal of Thermal Science》 SCIE EI CAS CSCD 2019年第5期905-914,共10页 热科学学报(英文版)
基金 support of the National Natural Science Foundation (No. 51776151 No.51936008 No. 51776173) of China supported by “the Fundamental Research Funds for the Central Universities” No. 3102019OQD702
关键词 gas TURBINE TURBINE ENDWALL COOLING trenched film HOLES PHANTOM COOLING numerical simulations gas turbine turbine endwall cooling trenched film holes phantom cooling numerical simulations
  • 相关文献

同被引文献19

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部