摘要
本文研究对象为由燃气内燃发电机组和烟气热水型溴化锂机组组成的燃气分布式能源成套机组。通过对机组进行制冷工况运行实验,并对实验参数与设计参数进行对比和分析,为燃气分布式能源成套机组的设计与应用提供指导意见。
The research object of this paper is the complete equipment of gas distributed energy which is consisting of the gas internal combustion generator set and the gas and hot water type lithium bromide absorption water air-conditioning.The unit is tested under refrigeration condition,and the experimental parameters and design parameters are compared and analyzed,then the guidance is provided for the design and application of the complete equipment of gas distributed energy.
作者
李冬波
谢吉平
方雷
吴同春
匡胜严
Li Dong-bo;Xie Ji-ping;Fang Lei;Wu Tong-chun;Kuang Sheng-yan
关键词
燃气分布式能源
成套装置
燃气内燃机
溴化锂吸收式空调
gas distributed energy
complete equipment
gas internal combustion engine
lithium bromide absorption water airconditioning