摘要 目的探讨研究动力髋螺旋刀系统(DHS-B)与3枚空心钉内固定治疗股骨颈骨折的临床疗效。方法自2014-07-2016-04收治股骨颈骨折86例,包括DHS-B组42例,空心钉组44例,比较分析2组的手术时间、出血量、切口长度、住院时间、术后髋关节Harris评分及并发症情况。结果所有患者术后获得随访,随访时间24~36(29.39±4.87)个月。空心钉组出血量比DHS-B组少,差异有统计学意义(P=0.04)。DHS-B组和空心钉组术后Harris评分、骨折不愈合率、股骨头坏死率、螺钉切出率比较,差异无统计学意义(P>0.05);空心钉组股骨颈短缩≥10 mm发生率高于DHS-B组,差异有统计学意义(P=0.02);空心钉组螺钉退出率高于DHS-B组,差异有统计学意义(P=0.04)。结论 DHS-B与空心钉治疗股骨颈骨折均能取得良好的临床疗效,但DHS-B较空心钉具有更低的股骨颈短缩、内固定移位及术后螺钉退出风险。
出处 《中国骨与关节损伤杂志》 2019年第8期836-838,共3页 Chinese Journal of Bone and Joint Injury
  • 相关文献

参考文献3

二级参考文献25

  • 1Chua IT, Rajamoney GN, Kwek EB, et al. Cephalomedullary nail versus sliding hip screw for unstable intertrochanteric fractures in elderly patients [J]. J Orthop Surg (Hong Kong) 2013;21(3):308-12. 被引量:1
  • 2Siwach RC, Rohilla R, Singh R, et al. Radiological and functional outcome in unstable, osteoporotic trochanteric fractures stablilized with dynamic helical hip system [J]. Strategies Trauma Limb Reconstr 2013;8(2): 117-22. 被引量:1
  • 3O Neill F, Condon F, McGloufhlin T, et al. Validity of synthetic bone as a substitute for osteoporotic cadaveric femoral heads in mechanical testing: a biomechanical study [J]. Bone Joint Res 2012;1(4):50-5. 被引量:1
  • 4Luo Q, Yuen G, Lau TW, et al. A biomechanical study comparing helical blade with screw design for sliding hip fixations of unstable intertrochanteric fractures [J]. Scientific World Journal 2013;2013:351936. 被引量:1
  • 5Sehmisch S, Rieckenberg J, Dresing K, et al. Stabilization of unstable intertrochanteric fractures with the proximal femoral nail [J]. Oper Orthop Traumatol 2013;25(1):63-83. 被引量:1
  • 6Niedzwiedzki L, Kunucki P, Pilut D, et al. Treatmentof reverse obliquity intertrochanteric fractures [J]. Pol Orthop Traumatol 2012;77:77-82. 被引量:1
  • 7Leung F, Gudushauri P, Yuen G, et al. Dynamic hip screw blade fixation for intertrochanteric hip fractures [J]. J Orthop Surg (Hong Kong) 2012;20(3):302-6. 被引量:1
  • 8Dousa P, Bartonicek J, Lunacek L, et al. Ipsilateral fractures of the femoral neck, shaft and distal end: long-term outcome of five cases [J]. Int Orthop 2011 ;35(7): 1083-8. 被引量:1
  • 9Wahnert D, Gudushauri P, Schiuma D, et al. Does cancellous bone compaction due to insertion of a blade implant influence the cut-out resistance? A biomechanieal study [J]. Clin Biomech 2010;25(10): 1053-7. 被引量:1
  • 10Akinci O, Akalin Y, Reisoglu, et al. Comparison of long- term results of dynamic hip screw and AO 130 degrees blade plate in adult trochanteric region fractures [J]. Acta Orthop Traumatol Turc 2010;44(6):443-51. 被引量:1