空调系统的能耗在卷烟厂中的占比很大,传统结构的组合式空调机组,夏季运行存在冷热抵消,不利于空调系统的节能运行。采用双通道结构的温湿分控设计方法,解决了空调系统夏季冷热抵消的弊端,在实际应用中取得明显的节能效果。
The energy consumption of air conditioning system takes up a large proportion in the cigarette factory.The heat and cold offset exists in the traditional combined air handling units in summer operation,which is not conducive to the energy saving operation of the air conditioning system.The design of separate control of temperature and humidity with double-channel structure is adopted to solve the drawback of heat and cold offset in the air conditioning system in summer,and obvious energy saving effect in practical application is achieved.
作者
姚如生
施斐炯
YAO Ru-sheng;Shi fei-jiong(Guangdong jirong air conditioning Co.,Ltd.,Jieyang 522000,China;Zhejiang Zhongyan Industry Co.,Ltd.,Ningbo 315000,China)
出处
《机电工程技术》
2019年第6期114-116,共3页
Mechanical & Electrical Engineering Technology
关键词
组合式空调机
双通道
温湿分控
节能
air handling units
double-channel
separate control of temperature and humidity