期刊文献+

离子色谱法测定水体中二氯乙酸含量的不确定度评定

Uncertainty Evaluation in Determination of Dichloroacetic Acid in Water by Ion Chromatography
下载PDF
导出
摘要 应用离子色谱法测定水中二氯乙酸,对盲样测定结果进行了不确定度评定。对不确定度的分析显示,其来源主要包括标准溶液自身、标准系列溶液稀释、曲线拟合过程和检测仪器等,计算各分量的相对不确定度分别为1.50%、0.405%、2.46%和1.60%。各分量最后拟合成标准不确定度,取置信概率为95%,包含因子k=2,获得测量结果的扩展不确定度,为今后水体中二氯乙酸含量的不确定度评定提供参考依据。 Dichloroacetic acid in water was determined by ion chromatography,and the uncertainty of the results of blind samples was evaluated.The uncertainty was also analyzed,the sources of which included standard solution itself,standard series solution dilution,curve fitting process and detection instrument.The relative uncertainty of each component was calculated to be 1.50%,0.405%,2.46%and 1.60%,respectively.Each component was finally fitted into standard uncertainty.The expanded uncertainty of measurement results was obtained by taking the confidence probability of 95%and the inclusion factor k=2,which provided some reference for the uncertainty evaluation of dichloroacetic acid content in water.
作者 甘晓娟 贾紫永 GAN Xiaojuan;JIA Ziyong(Water Quality Monitoring Network of National Urban Water Supply Monitoring Station qf Chongqing,Chongqing 400074,China;Polar Membrane Environmental Technology(Shanghai)Co.,Ltd.,Shanked 201200,China)
出处 《净水技术》 CAS 2019年第A01期29-31,共3页 Water Purification Technology
关键词 离子色谱法 水体 二氯乙酸 不确定度 ion chromatography water dichloroacetic acid uncertainty
  • 相关文献

参考文献5

二级参考文献11

共引文献39

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部