期刊文献+

可穿戴织物心电电极运动伪迹的产生机制与抑制方法 被引量:8

The causes and suppression methods of motion artifacts of wearable textile electrocardio-electrodes
下载PDF
导出
摘要 织物电极具有柔软、舒适、易于集成于服装、便于长期穿戴等优点,因而成为智能可穿戴的一个研究热点。织物电极用于心电信号检测时,不像传统湿电极那样直接黏贴在皮肤上,因此其运动伪迹问题较湿电极更为突出,并成为制约织物电极应用的最重要因素。基于织物电极的简化电路模型和心电电压公式,结合已有研究成果,剖析织物心电电极运动伪迹产生的具体原因,并尝试从根本上分析相应的抑制方法,为织物心电电极的设计提供参考。 Textile electrode has the advantages of being soft, comfortable,and easy to be integrated into the garments and worn for a long time, etc., so it becomes a research focus in intelligent wearable field. Compared to traditional wet electrodes, textile electrodes are not pasted onto the skin when monitoring ECG, thus,they have more motion-artifact questions, which becomes a significant factor of restricting textile electrodes′ application. Based on simplified circuit models and ECG voltage formula of textile electrodes,together with existing research findings, the specific causes of motion artifacts are analyzed,trying to analyze corresponding suppression method for the design of textile electrodes.
作者 杨红英 叶华标 周金利 张焕焕 陈东义 YANG Hongying;YE Huabiao;ZHOU Jinli;ZHANG Huanhuan;CHEN Dongyi(College of Textiles,Zhongyuan University of Technology, Zhengzhou 450007,China;College of Automation Engineering,University of Electronic Science and Technology of China, Chengdu 611173,China)
出处 《纺织高校基础科学学报》 CAS 2019年第2期126-132,共7页 Basic Sciences Journal of Textile Universities
基金 国家自然科学基金(61572110) 国家重点研发计划(2016YFB1001401)
关键词 织物电极 运动伪迹 可穿戴 心电图 textile electrodes motion artifacts wearable electrocardiogram
  • 相关文献

参考文献13

二级参考文献126

  • 1岳蜀华,王美涵,郭飞,孟兆辉,白净,王保华(审校者).可穿戴式无线心电监测仪的研究现状[J].生物医学工程与临床,2006,10(4):262-266. 被引量:30
  • 2郭劲松,邓亲恺.可穿戴式心电、呼吸传感器与检测系统的研制[J].中国医疗器械杂志,2006,30(5):341-344. 被引量:23
  • 3李卫娜,侯文生,郑小林,彭承琳.基于Electrooculogram的眼动信息识别[J].仪器仪表学报,2007,28(8):1428-1433. 被引量:5
  • 4郝红伟,马伯志,李路明,曹洋.基于双电极的心电测量方法及仪器[J].航天医学与医学工程,2007,20(5):372-375. 被引量:4
  • 5Giorgino T, Tormene P. Wireless support to poststroke reha- bilitation: MyHeart's neurological rehabilitation concept [J]. Information Technology in Biomedicine, IEEE Trans- actions on,2009, 13(6):1012-1018. 被引量:1
  • 6Heilman K J, Porges S W. Accuracy of the Life shirt(Vivo- metrics) in the detection of cardiac rhythms [ J ]. Biological Psychology, 2007 (3) : 300-305. 被引量:1
  • 7Cho G, Jeong K, Paik M J, et al. Performance evaluation of textile-based electrodes and motion sensors for smart cloth- ing[ J ]. Sensors Journal, IEEE, 2011,11 (12) : 3183-3193. 被引量:1
  • 8Kang T H, Merritt C R, Grant E, et al. Nonwoven fabric active electrodes for biopotential measurement during nor-mal daily activity [ J ]. Biomedical Engineering, IEEE Trans- actions on, 2008,55( 1 ) : 188-195. 被引量:1
  • 9Merritt C R, Nagle H T, Grant E. Fabric-based active elec- trode design and fabrication for health monitoring clothing [ J 1. Information Technology in Biomedicine, IEEE Tran- nsactions on, 2009, 13 (2) : 274-28. 被引量:1
  • 10郭继鸿;张萍.动态心电图学[M]北京:人民卫生出版社,2003. 被引量:1

共引文献112

同被引文献66

引证文献8

二级引证文献43

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部