摘要 火焰原子吸收法在环境监测领域对地表水、地下水及废水中痕量溶解态或总量金属元素的定量分析已经得到了广泛的应用和发展。它具有测试灵敏度高、准确性好、简便快捷等优点。以火焰原子吸收针对火焰原子光谱仪测定金属项目的测试方法、灯电流、锐线光谱、狭缝宽度、燃烧器高度等测试条件的选择、样品前处理过程、分析测试质量控制等方面做了简要介绍,对操作者更好的使用该仪器具有指导意义。 Flame atomic absorption spectrometry (FAAS) has been widely used and developed in the field of environmental monitoring for the quantitative analysis of trace dissolved or total metal elements in surface water, groundwater and wastewater. It has the advantages of high sensitivity, good accuracy, simplicity and rapidity. Flame atomic absorption spectrometry (FAAS) for the determination of metal items was introduced, such as test methods, lamp current, sharp line spectroscopy, slit width, burner height, sample pretreatment process, analysis and test quality control. It had guiding significance for operators to better use the instrument.
作者 张宝军 闫小川 ZHANG Bao-jun;YAN Xiao-chuan(Pingliang Environmental Monitoring Station, Gansu Pingliang 744099;Department of Biochemistry, Pingliang Vocational and Technical College, Gansu Pingliang 744000, China)
出处 《广州化工》 CAS 2019年第9期32-33,67,共3页 GuangZhou Chemical Industry
基金 2018年度甘肃省高等学校科研项目一般项目(2018A-286)
关键词 火焰原子光谱仪 测定金属 注意事项 flame atomic spectrometry determination of metal the attention matters