摘要
某氯碱企业氯气压缩机连续因电动机绕组温度高报导致非计划停车,影响了生产装置的安全平稳运行。对氯气压缩机电动机绕组测温进行冗余处理,成功解决了非计划停车的问题。
The chlorine compressor continuously unplanned shutdown in a chlor-alkali enterprise due to the high temperature alarm of the motor winding,and the safe and stable operation of the production plant was affected.The problem of unplanned shutdown was successfully solved by temperature measurement redundancy of motor windings for chlorine compressor.
作者
杨友信
曹潭洲
李生虎
YANG Youxin;CAO Tanzhou;LI Shenghu(Tianneng Chemical Industry Co.,Ltd.,Shihezi 832012,China)
出处
《氯碱工业》
CAS
2019年第5期38-39,42,共3页
Chlor-Alkali Industry
关键词
氯气压缩机
电动机绕组
测温元件
冗余设计
chlorine compressor
motor winding
temperature measuring element
redundancy design