摘要 分析了某石化延迟焦化富气压缩机造成防喘振阀关不严的几个原因,结合现场实际性能试验,绘制压缩机性能曲线,确定了造成压缩机防喘振阀关不严的原因。重新修改压缩机数据表,最终换转子,彻底解决了防喘振阀关不严的故障,节能效果显著。 The purpose of this paper is to analyze several reasons for the lax control of the anti-surge valve caused by a petrochemical delayed coking gas-rich compressor, and to draw the performance curve of the compressor through the actual performance test in the field, and to determine the reason for the lax anti-surge valve of the compressor. Modify the compressor datasheet, and eventually change the rotor,completely solve the anti-surge valve is not strict failure, energy-saving effect is significant.
作者 武生祥 洪伟鸿 姚茂祥 于鑫淼 Wu Shengxiang;Hong Weihong;Yao Maoxiang;Yu Xinyu(PetroChina Guangdong Petrochemical Company Lanzhou City, Gansu Province 515200)
出处 《云南化工》 CAS 2019年第2期39-40,43,共3页 Yunnan Chemical Technology
关键词 富气压缩机 防喘振阀故障 现场试验 转子改造 节能 rich gas compressor anti-surge valve failure rotor modification energy saving