摘要
以浙江宁波某滨海污水处理厂为例,对该工程的结构现状进行分析,并通过结构静力计算与有限元分析,对其污水池进行结构改造的防水抗渗优化设计,最终达到了良好的优化效果。
Taking a coastal sewage treatment plant in Ningbo,Zhejiang province as an example,the structure status of the project was analyzed,and through the structural static calculation and finite element analysis,the structure of the sewage tank was reconstructed and the waterproof and impermeable design was optimized,and finally achieved good optimization effect.
作者
凌保林
LING Bao-lin(Shanghai Urban Construction Design Research General Institute (Group) Co.Ltd.,Shanghai 200125,China)
出处
《工程建设与设计》
2019年第7期36-38,共3页
Construction & Design for Engineering