摘要 二次侧非能动余热排出(ASP)系统是国内二代加型百万千瓦级压水堆核电厂应对全厂断电事故的重要改进项。为获取ASP系统的启动特性,基于比例模化方法设计建造了ASP系统试验装置。试验结果获取了不同因素对ASP系统启动特性的影响。结果表明:蒸汽发生器二次侧水装量与ASP系统隔离阀动作时间对ASP系统的启动特性影响较小;ASP系统的流量随蒸汽管线与回水管线阻力系数的增大而降低;蒸汽释放阀(VDA)的往复开启引起自然循环流量的波动,当VDA关闭后自然循环可恢复至稳定状态;换热管内初装水的水量影响ASP系统初始流量峰值;所有试验工况中均建立了稳定的自然循环。 Advanced secondary passive residual heat removal(ASP)system is one of the most important improving measures to cope with station blackout accident in the domestic second generation+1 000 MWe PWR nuclear power plant.In order to obtain the starting performance of ASP system,the ASP system test facility was constructed based on scaling criteria.The effects of different influencing factors on starting performance of ASP system were obtained.The results show that the secondary-side water inventory of steam generator and operating time of ASP system isolation valve have little influence on starting performance of ASP system.The flow rate of ASP system decreases with the increase of drag coefficient of steam pipeline and backwater pipeline.The flow rate of ASP system is unstable with reciprocating opening of vapor discharge to atmosphere valve(VDA),and it is recovered to stable state when VDA is closed.The peak value of flow rate of ASP system is mainly affected by the initial water volume of heat exchanger tube.The stable natural circulation is established during all the experiments.
作者 李亮国 龙彪 孙振邦 许严阵 苏前华 吴小航 卢冬华 朱峰 LI Liangguo;LONG Biao;SUN Zhenbang;XU Yanzhen;SU Qianhua;WU Xiaohang;LU Donghua;ZHU Feng(China Nuclear Power Technology Research Institute,Shenzhen 518026,China;China Nuclear Power Technology Engineering Co.,Ltd.,Shenzhen 518026,China)
出处 《原子能科学技术》 EI CAS CSCD 北大核心 2019年第4期641-647,共7页 Atomic Energy Science and Technology
关键词 二次侧非能动余热排出系统 启动特性 影响因素 试验研究 advanced secondary passive residual heat removal system starting performance influencing factor experimental investigation
  • 相关文献

参考文献4

二级参考文献15

  • 1Nuclear Regulatory Commlsslon. Vmal satety e- valuation report related to certification of the AP1000 standard design (NUREG-1793)[R/ OL]. USA: Nuclear Regulatory Commission, 2004[2010-07-08]. http://www, nrc. gov/read- ing-rm/doc-collection s / n uregs/ staff/ sr17 9 3 / cha- pter21, pdf. 被引量:1
  • 2LOUIS M S, YUTAKA K. Implication of the ROSA/AP600 high- and intermediate pressure test results[J]. Nuclear Technology, 1997, 199 (3) : 217-233. 被引量:1
  • 3REYES N J, LAWRENCE H. Scaling analysisfor the OSU AP600 test facility (APEX)[J]. Nuclear Engineering and Design, 1998, 186(1- 2) : 53-109. 被引量:1
  • 4秦本科,李玉全,张子扬,等.非能动堆芯冷却系统整体性能试验台架比例设计报告[R].北京:国家核电技术研发中心,2010. 被引量:3
  • 5REYES N J, WU Q, KING B J. Scaling assess- ment for the design of the OSU APEX-1000 test facility, OSU-APEX-03001 [R] n. 7, 2003. 被引量:1
  • 6KOCAMUSTAFAOGULLARI G, ISHII M. Scaling of two-phase flow transients using re- duced pressure system and stimulant fluid [J].Nuclear Engineering and Design, 1987, 104(2) 121-132. 被引量:1
  • 7ISHII M, KATAOKA I. Scaling laws for ther- mal-hydraulic system under single phase and two- phase natural circulation[J]. Nuclear Engineer- ing and Design, 1984, 81(3): 411-425. 被引量:1
  • 8ISHII M, REVANKAR S T, LEONARDI T, et al. The three-level scaling approach with applica- tion to the Purdue University multi-dimensional integral test assemble (PUMA)[J]. Nuclear En- gineering and Design, 1998, 186(1-2): 177-211. 被引量:1
  • 9Westinghouse. Low-pressure integral systemstest facility scaling report, WCAP-14270 [R]. Pittsburgh: Westinghouse Electric Coporation, 1997. 被引量:1
  • 10SCHWARTZBECK R K, KOCAMUSTAFAOGU- LLARI G. Similarity requirement for two-phase flow-pattern transitions[J]. Nuclear Engineering and Design, 1989, 116(2): 135-147. 被引量:1