期刊文献+

中压开关柜运行状态监测系统设计 被引量:2

Design of Operating Status Monitoring System for Medium Voltage Switchgear
下载PDF
导出
摘要 中压开关柜是电力系统中重要的电气设备,为保证中压开关柜的可靠运行,降低故障发生率,提高电力系统安全,提出基于数字信号处理器的运行状态监测系统。在分析中压开关柜特点和发展趋势的基础上,利用数字信号处理器为核心处理器设计中压开关柜运行状态监控系统,分别设计硬件整体结构、声光报警模块和软件程序。 Medium voltage switchgear is an important electrical equipment in the power system.An operation status monitoring system based on digital signal processor is proposed to ensure the reliable operation of medium voltage switchgear.It can reduce the failure rate and improve safety of the power system.Based on the analysis of the characteristics and development trend of the medium voltage switchgear,the digital signal processor is used as the core processor to design the operation status monitoring system of the medium voltage switchgear.The hardware overall structure,sound and light alarm module,and software program are designed respectively.
作者 田天 白凯帆 TIAN Tian;BAI Kai-fan(Automated System Project Limited Company of Shenyang Blower Works Group Corporation,Shenyang 110006,China)
出处 《电工材料》 CAS 2019年第1期35-37,共3页 Electrical Engineering Materials
关键词 中压开关柜 温度 弧光 监测 medium voltage switchgear temperature arc monitoring