摘要
国内恒电位仪采用单一参比电极作为控制参比,对于复杂管路的循环水管道单一参比电极很难表征整个系统的阴极保护状况,本文从保护电流密度角度对循环水管道阴极保护水平进行评估。
Potentiostat using a single reference electrode control C-P system in china. Single reference electrode is difficult to characterize the cathodic protection status of the entire system for complex piping recycled water piping. This article from the perspective of the protection current density of recycled water pipeline cathodic protection assessing the level.
作者
马光皎
李军威
丁继峰
MA Guang-jiao;LI Jun-wei;DING Ji-feng(Qingdao NCS Testing&Corrosion Protectiong Technology Co.,Ltd. Qingdao 266071,China)
出处
《全面腐蚀控制》
2019年第1期59-62,共4页
Total Corrosion Control