期刊文献+

TN系统电源中性点接地方式探讨 被引量:3

Discussion on Power Neutral-point Grounding Mode of TN System
下载PDF
导出
摘要 对单母线分段接线、多电源系统、常见TN系统电源中性点接地方式接线做法进行分析和比较,提出能满足规范和功能要求的两种接线方式。对常见的一点接地的接线做法进行调整和优化,对两种接地方式接线做法的适用范围进行阐述。 The wiring practices of power neutral-point grounding modes for the sectionalized single-bus connection,the multi-power supply system and the power supply to common TN system are analyzed and compared to put forward two wiring modes that can meet the code and functions requirements.The common one-point grounding wiring practices are adjusted and optimized,and the scope of application of the two grounding wiring practices are elaborated.
作者 李蜀光 LI Shuguang(Chongqing Architectural Design Institute of China,Chongqing 400015,China)
机构地区 重庆市设计院
出处 《建筑电气》 2019年第2期31-36,共6页 Building Electricity
关键词 TN系统 单母线分段接线 多电源系统 电磁兼容性 一点接地 电源转换开关 保护接地 功能接地 接地故障 等电位联结 TN system sectionalized single-bus connection multi-power supply system electromagnetic compatibility one-point grounding power changeover switch protective grounding functional grounding ground fault equipotential bonding
  • 相关文献

参考文献3

二级参考文献17

共引文献19

同被引文献11

引证文献3

二级引证文献3