原油密度是很重要的分析数据,不仅事关原油交接贸易的公平公正,还直接关系到管道公司和炼化企业的经济利益。因此,对原油双方密度测量误差来源进行梳理研讨,有助于解决贸易纠纷。(本文)通过对管道公司原油末站自采仪和企业接收罐前自采仪密度数据对比及存贮挥发性试验,分析探讨了化验数据差异的原因。
Crude oil density is an important analytical data,It is not only related to the fairness of crude oil transfer trade,but also directly related to the economic interests of pipeline companies enterprises.Therefore,it is helpful to sort out and discuss the sources of density measurement errors between the two sides of crude oil to solve disputes.This papar analyzed and discussed the reasons for the differenes in the test data by comparing the density data of the automatic petroleum collector at the end of oil station of the pipeline company with that of the automatic petroleum collector before receiving the tank of the enterprise and by the storage volatility test.
作者
韩海外
Han Haiwai(Inspection and Metering Center of Anqing Petrochemical Company,SINOPEC,Anqing 246001)
出处
《石化技术》
CAS
2019年第1期2-4,共3页
Petrochemical Industry Technology
关键词
原油交接
密度误差
挥发性
试验
原因分析
crude oil transfer
the density of error volatile
test
cause analysis