文章以榆能集团佳县盐化有限公司120万t/a真空制盐项目包装仓储火灾自动报警系统设计为例,结合《建筑防火设计规范》及《火灾自动报警系统设计规范》的要求,介绍了在火灾自动报警系统联动控制、系统供电、布线、系统接地设计理念及设计中需要注意的一些问题。
Taking the design of automatic fire alarm system for packing and storage of 1. 2 million tons/year vacuum salt making project in Jiaxian Salt Chemical Co.,Ltd. of Yuneng Group as an example,this article which combined the requirements of Building Fire Protection Design Code and Fire Automatic Alarm System Design Code introduced the design concept of linkage control,system power supply,wiring,system grounding of automatic fire alarm system and some problems needing attention in the design.
作者
贡鑫
刘云环
刘军
GONG Xin;LIU Yun-huan;LIU Jun(Engineering Technology Institute Co.,Ltd., CNSIG, Tianjin 300450, China)
出处
《盐科学与化工》
CAS
2018年第12期42-44,共3页
Journal of Salt Science and Chemical Industry
关键词
火灾自动报警系统
联动控制
系统供电
Automatic fire alarm system
Linkage control
System power supply