期刊文献+

Fenton+BAF工艺在化工园区尾水深度处理中的应用 被引量:4

Application of the combined process Fenton + BAF to the advanced treatment of tail water in chemical industrial parks
下载PDF
导出
摘要 介绍了一种化工园区尾水深度处理工艺——Fenton+BAF组合工艺。工艺运行效果表明:当系统进水COD在140 mg/L左右时,组合工艺对COD的去除率可达到55%,其中Fenton氧化工艺COD去除率达到40%,BAF工艺COD去除率达到30%,出水水质能够稳定达标,系统运行费用约2.94元/t。传统Fenton氧化池的HRT可优化至3 h;BAF池在前2.5 h的停留时间内,对废水COD、氨氮的削减幅度相对较高,COD削减量可达到20%。 A kind of advanced treatment process of tail water in chemical industrial parks-the combined process Fenton+BAF is introduced.The process running effect shows that when the system influent COD is about 140 mg/L,the COD removing rate by the combined process can reach 55%,of which the COD removing rate by Fenton oxidation process reaches 40%,and that by BAF process reaches 30%.The effluent water quality can stably reach the stand-ard.The running cost of the system is about RMB 2.94 per ton.The HRT of traditional Fenton oxidation pond can be optimized to 3 h.Within the first 2.5 h of HRT time,the reduction range of wastewater COD and ammonia nitrogen of BAF pond is relatively high,the COD reduction capacity can reach 20%.
作者 潘兴华 蔡国飞 Pan Xinghua;Cai Guofei(Yancheng Academy of Environmental Protection Technology and Engineering,Nanjing University,Nanjing 211100,China)
出处 《工业水处理》 CAS CSCD 北大核心 2018年第10期98-101,共4页 Industrial Water Treatment
关键词 FENTON氧化 曝气生物滤池 化工园区尾水 Fenton oxidation biological aerated filter tail water of chemical industrial parks
  • 相关文献

参考文献5

二级参考文献35

  • 1刘金香,娄金生,陈春宁.沸石-陶粒曝气生物滤池处理微污染水源水试验[J].工业用水与废水,2005,36(4):10-12. 被引量:18
  • 2胡保安,连立国,倪福功,纪轩,顾平.曝气生物滤池深度处理石化废水的试验研究[J].中国给水排水,2007,23(7):66-69. 被引量:21
  • 3章胜红,陈季华,孙志国.曝气生物滤池废水深度处理同步硝化反硝化机理及影响因素[J].东华大学学报(自然科学版),2007,33(1):125-129. 被引量:13
  • 4Zhao X, Wang Y M, Ye Z F, et al. Oil field wastewater treatment in Biological Aerated Filter by immobilized microorganisms [ J]. Process Biochem, 2006, 41(7) : 1475-1483. 被引量:1
  • 5Wang X J, Chen S L, Gu X Y, et al. Biological aerated filter treated textile washing wastewater for reuse after ozonation pretreatment [J]. Water Sci Technol, 2008, 58(4) : 919-923. 被引量:1
  • 6Ryu H D, Kim D, Lim H E, et al. Nitrogen removal from low carbon-to-nitrogen wastewater in four-stage biological aerated filter system [J]. Process Biochem, 2008, 43(7) : 729-735. 被引量:1
  • 7He S B, Xue G, Kong H N. The performance of BAF using natural zeolite as filter media under conditions of low temperature and ammonium shock lead [J]. J Hazard Mater, 2007, 143(1-2): 291- 295. 被引量:1
  • 8Wang S T, Ma J, Liu B C, et al. Degradation characteristics of secondary effluent of domestic wastewater by combined process of ozonation and biofihration [ J ]. J Hazard Mater, 2008, 150 ( 1 ) :109-114. 被引量:1
  • 9Hu J Y, Ong S L, Ng W J, etal. A new method for characterizing denitrifying phosphorus removal bacteria by using three different types of electron acceptors [ J]. Water Res, 2003, 37(14) : 3463-3471. 被引量:1
  • 10Zhu S N, Ni J R. Treatment of coking wastewater by a UBF-BAF combined process [J]. J Chem Technol Biot, 2008, 83(3): 317- 324. 被引量:1

共引文献91

同被引文献60

引证文献4

二级引证文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部