期刊文献+

Sensitivity Investigation and Optimization for Solar Irradiance Absolute Radiometer

Sensitivity Investigation and Optimization for Solar Irradiance Absolute Radiometer
下载PDF
导出
摘要 Since the calibration accuracy decreases with the reduction of irradiance power,the nonlinearity of sensitivity is experimentally investigated and corrected in order to improve the precision of calibration for Solar Irradiance Absolute Radiometer( SIAR). The optimization method is proposed based on the interpolation approximation principle. The real-time correction sensitivities are repeatedly measured at each radiant power.The relative system error of sensitivity nonlinearity is 2.2%. The impact of sensitivity nonlinearity is analyzed.The radiant powers are measured by the optimization method and the traditional method. The comparison experiment results illustrate that the optimization method improves the measure accuracy to 0. 1%. The sensitivity nonlinearity is compensated by the real-time correction. Thus,the optimization method significantly improves the calibration precision of ground-based comparison experiment. The investigation of sensitivity nonlinearity also provides the theoretical and experimental basis for optimizing the on-orbit calibration precision of Total Solar Irradiance Monitor( TSIM). Since the calibration accuracy decreases with the reduction of irradiance power,the nonlinearity of sensitivity is experimentally investigated and corrected in order to improve the precision of calibration for Solar Irradiance Absolute Radiometer( SIAR). The optimization method is proposed based on the interpolation approximation principle. The real-time correction sensitivities are repeatedly measured at each radiant power.The relative system error of sensitivity nonlinearity is 2.2%. The impact of sensitivity nonlinearity is analyzed.The radiant powers are measured by the optimization method and the traditional method. The comparison experiment results illustrate that the optimization method improves the measure accuracy to 0. 1%. The sensitivity nonlinearity is compensated by the real-time correction. Thus,the optimization method significantly improves the calibration precision of ground-based comparison experiment. The investigation of sensitivity nonlinearity also provides the theoretical and experimental basis for optimizing the on-orbit calibration precision of Total Solar Irradiance Monitor( TSIM).
出处 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2017年第4期50-56,共7页 哈尔滨工业大学学报(英文版)
基金 Sponsored by the National Natural Science Foundation of China(Grant Nos.41227003 and 41474161)
关键词 MEASURE PRECISION ABSOLUTE RADIOMETER radiant calibration SOLAR IRRADIANCE measure precision absolute radiometer radiant calibration solar irradiance
  • 相关文献

参考文献5

二级参考文献33

共引文献48

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部