本文介绍了低温等离子的原理、优点、质量控制的方法,总结了设备的常见故障现象及保养经验。运用ISO9001质量控制体系对等离子设备发生的不良事件进行风险评估,我院把该类设备列入高风险设备管理,采取了增加设备数量、提高工程师维修技能、加强操作使用人员培训等方法,有效地控制了风险。
This paper introduced the principle,advantages and the quality control method of low temperature plasma,and summed up the common equipment failure and maintenance experience.With application of ISO9001quality control system to evaluate the risk of plasma adverse events occurred in our hospital,the plasma equipment was added to the list of high-risk equipment to manage,and taken some measures such as increasing the number of devices,improving engineer's maintenance skills and strengthening the operation personnel training,which realized effective control of risk.
作者
严浩
路鹤晴
YAN Hao;LU He-qing(Department of Medical Equipment,Shanghai First Maternity and Infant Hospital, Tongji University School of Medicine, Shanghai 201204, China)
出处
《中国医疗设备》
2017年第5期163-165,共3页
China Medical Devices
关键词
低温等离子
风险评估
风险控制
设备维修
灭菌器
low temperature plasma
risk assessment
risk control
equipment maintenance