摘要 低温省煤器系统的改造优化可提高锅炉运行效率与节省煤炭用量。采用理论分析,结合相关案例,对技术要点、关键问题和控制措施等改造方案进行了分析研究。改造后,低温省煤器入口水温控制在70℃以上,出口排烟温度控制在95℃以上,烟气压差控制在200~300Pa。实践表明:加强对低温省煤器的入口水温和出口烟气温度的控制,管控好烟气压差等相关指标,全面进行系统监测,锅炉低温省煤器改造优化方案可行。 Transformation and optimization on low temperature economizer system can improve theefficiency of a boiler and save its coal consumptions.In combination with theoretical analysis and casestudy,research is carried out on specific transformation schemes such as key technological points,coreproblems and control measures,etc.After such a transformation,its inlet water temperature is controlled at70℃above,its outlet exhaust gas temperature is controlled at95℃above,and its gas pressure differentialis controlled between200to300Pa.It is deduced from the practice that,the main idea for transformationand optimization on low temperature economizer for boilers is to strengthen the control on inlet watertemperature,outlet exhaust gas temperature as well as related indicators such as gas pressure differential,and conduct a systematic comprehensive monitoring.
作者 杨恒宇 YANG Heng-yu(Jiaozuo Power Plant, Shenhua Guoneng Energy Group Co., Ltd., Jiaozuo, Henan, 454351, China)
出处 《工业技术创新》 2016年第6期1195-1197,共3页 Industrial Technology Innovation
关键词 锅炉 低温省煤器 烟气温度 烟气压差 自动控制 Boiler Low Temperature Economizer Exhaust Gas Temperature Gas Pressure Differential Automatic Control
  • 相关文献

参考文献7

  • 1靖长财.锅炉低温省煤器改造系统设计的对应措施[J].神华科技,2015,13(5):49-52. 被引量:3
  • 2赫向辉..大型燃煤锅炉低温烟气余热综合利用及节能分析[D].华北电力大学,2015:
  • 3张鑫..锅炉烟气余热利用系统分析与优化研究[D].华北电力大学,2015:
  • 4陆万鹏..基于电站锅炉排烟余热的机炉烟气回热循环理论与应用研究[D].山东大学,2012:
  • 5刘嘉楷..空冷机组余热高效利用系统的设计与优化研究[D].华北电力大学,2014:
  • 6张昌顺..锅炉烟气余热利用系统流程优化及关键设备实验[D].华北电力大学,2014:
  • 7王际洲..燃煤发电机组热力系统机理模型及非设计工况运行特性研究[D].华中科技大学,2015: