期刊文献+

Analysis of residual crosslinking agent content in UV cross-linked poly(ethylene oxide) hydrogels for dermatological application by gas chromatography 被引量:1

Analysis of residual crosslinking agent content in UV cross-linked poly(ethylene oxide) hydrogels for dermatological application by gas chromatography
下载PDF
导出
摘要 Acrylates have been widely used in the synthesis of pharmaceutical polymers. The quantitation of residual acrylate monomers is vital as they are strong irritants and allergens, but after polymerization, are relatively inert, causing no irritation and allergies. Poly(ethylene oxide)(PEO) hydrogels were prepared using pentaerythritol tetra-acrylate(PETRA) as UV crosslinking agent. A simple, accurate, and robust quantitation method was developed based on gas chromatographic techniques(GC), which is suitable for routine analysis of residual PETRA monomers in these hydrogels. Unreacted PETRA was initially identified using gas chromatography–mass spectrometry(GC–MS). The quantitation of analyte was performed and validated using gas chromatography equipped with a flame ionization detector(GC–FID). A linear relationship was obtained over the range of 0.0002%–0.0450%(m/m) with a correlation coefficient(r2)greater than 0.99. The recovery( 4 90%), intra-day precision(%RSD o 0.67), inter-day precision(%RSD o2.5%), and robustness(%RSD o1.62%) of the method were within the acceptable values. The limit of detection(LOD) and limit of quantitation(LOQ) were 0.0001%(m/m) and 0.0002%(m/m), respectively.This assay provides a simple and quick way of screening for residual acrylate monomer in hydrogels. Acrylates have been widely used in the synthesis of pharmaceutical polymers. The quantitation of residual acrylate monomers is vital as they are strong irritants and allergens, but after polymerization, are relatively inert, causing no irritation and allergies. Poly(ethylene oxide)(PEO) hydrogels were prepared using pentaerythritol tetra-acrylate(PETRA) as UV crosslinking agent. A simple, accurate, and robust quantitation method was developed based on gas chromatographic techniques(GC), which is suitable for routine analysis of residual PETRA monomers in these hydrogels. Unreacted PETRA was initially identified using gas chromatography–mass spectrometry(GC–MS). The quantitation of analyte was performed and validated using gas chromatography equipped with a flame ionization detector(GC–FID). A linear relationship was obtained over the range of 0.0002%–0.0450%(m/m) with a correlation coefficient(r2)greater than 0.99. The recovery( 4 90%), intra-day precision(%RSD o 0.67), inter-day precision(%RSD o2.5%), and robustness(%RSD o1.62%) of the method were within the acceptable values. The limit of detection(LOD) and limit of quantitation(LOQ) were 0.0001%(m/m) and 0.0002%(m/m), respectively.This assay provides a simple and quick way of screening for residual acrylate monomer in hydrogels.
机构地区 Department of Pharmacy
出处 《Journal of Pharmaceutical Analysis》 SCIE CAS 2016年第5期307-312,共6页 药物分析学报(英文版)
关键词 Poly(ethylene oxide) (PEO) RESIDUAL MONOMER HydrogelGas chromatography–mass spectrometry (GC–MS) Gas chromatography–flame ionization detection (GC–FID) Poly(ethylene oxide)(PEO) Residual monomer Hydrogel Gas chromatography–mass spectrometry(GC–MS) Gas chromatography–flame ionization detection(GC–FID)
  • 相关文献

同被引文献3

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部