期刊文献+

丙氨酸转氨酶参考品的研制 被引量:2

Experimental production on reference material for alanine aminotransferase
下载PDF
导出
摘要 目的研制用于丙氨酸转氨酶 (ALT)测定的参考品。方法猪心作原料 ,经硫酸铵沉淀、DEAE SephadexA 5 0、CM SephadexC 5 0、SephadexG 15 0及抗天冬氨酸转氨酶 (AST)免疫亲和色谱提纯 ,用一定的基础液稀释后分装冻干。结果提纯品ALT比活为 173U/mg蛋白 ,得率 2 2 .8% ,温度加速变性试验测得预期年失活率 ,在 - 2 0℃、4℃分别为 0 .0 5 %、0 .12 %。结论此法提纯ALT得率高 ,仅含少量AST ,冻干品稳定 ,在不同方法间与人血清有互换性 。 PurposeTo prepare a stable and intermethod properties.MethodsThe enzyme was purified from hog heart by ammonium sulfate precipitation and chromatography successively on DEAE Sephadex A50?CM Sephadex C50?Sephadex G150 and immuno affinity column of anti AST antibodies. The purified enzyme was diluted with a well defined matrix, dispensing in vials,and lyophylizing.ResultsThe purified enzyme had a specific activity of 166 kU/g protein.The yearly loss of activity for the preparation of lyophyized on the basis of accelerated degradation tests was 0.05% at -20℃, 0.12% at 4℃, respectively. Preliminary assigned value for ALT catalytic activity concentration in the reconstituted lyophilized material was 201 U/L with a 0.95 confidence interval of ± 4.9 U/L when measured by the IFCC method (without PLP) at 37℃.Conclusion The material possesses the long term stability and the comutability. It is suitable as calibrator or candidate reference material (uncertified) in clinical enzyme assay.
出处 《中国生化药物杂志》 CAS CSCD 2002年第5期223-225,共3页 Chinese Journal of Biochemical Pharmaceutics
基金 军队医药卫生基金资助课题 (96M0 2 0 )
关键词 丙氨酸转氨酶 酶参考品 临床酶学 alanine aminotransferase reference material
  • 相关文献

参考文献12

  • 1文庆成.临床酶测定标准化的几个问题[J].中华医学检验杂志,1998,21(1):60-61. 被引量:29
  • 2Schiele F, Muller J, Colinet E,et al. Interlaboratory study of the IFCC method for alanine aminotransferase performed with use of a partly purified reference material[J]. Clin Chem,1992, 38:2365-2371. 被引量:1
  • 3Jenkins WT, Saier M. Methods in Enzymology [M]. New York: Acadimic Press, 1970.17A159-17A163. 被引量:1
  • 4Rej R, Vanderlinde RE, Fasce CF. An L-aspartate α-oxoglutarate aminotransferase reference material from human erythrocytes: Preparation and characterization [J]. Clin Chem, 1972, 18:374-384. 被引量:1
  • 5Garvey JS, Cremer NF, Sussdorf DH. Methods in immunology[M]. Massachusetts: Addison-wesley,3rd ed. 1977.218-219, 245-255. 被引量:1
  • 6Bergmeyer J. Methods of enzymatic analysis III[M].Werlag Chemie GmbH, 1983.216-225. 被引量:1
  • 7Bergmeyer HU,Horder M,Rej R. Approved recommedation(1985) on IFCC methods for the measurement of catalytic concentration of enzymes. Part 3. IFCC method for alanine amintransferase[J]. J Clin Chem Clin Biochem, 1986, 24:481-495. 被引量:1
  • 8Hartree EF. Determination of protein. A modification of the Lowry method that gives a linear photometric response [J]. Anal Biochem,1972,48:422-427. 被引量:1
  • 9孟泽,史利宁,李勇,黄宇峰.胰α-淀粉酶参考品的实验研究[J].中国生化药物杂志,2002,23(1):11-14. 被引量:3
  • 10Rej R. Accurate enzyme activity measurements-Two decades of development in the commutability of enzyme quality control materials[J]. Arch Pathol Lab Med,1993,117:352-364. 被引量:1

二级参考文献23

共引文献35

同被引文献23

  • 1朱汉明,柯三才,周新,漆林涛.线粒体谷丙转氨酶的分离、纯化及其性质的研究[J].湖北医科大学学报,1994,15(2):158-160. 被引量:1
  • 2邓慧珍.单纯丙氨酸氨基转移酶升高并不等于肝病[J].实用医技杂志,2006,13(7):1098-1099. 被引量:7
  • 3王抒,李培瑛,陈文祥,董军,蒋雷,国汉邦,唐蔚青,李红霞,李健斋.血清胆固醇标准参考物质的研制[J].中华医学检验杂志,1996,19(4):216-219. 被引量:7
  • 4European Union. Directive 98/79/EC of the european parliament and of the council of 27 October 1998 on in vitro diagnostic medical devices. OffJ Euro Commun, 1998,1331 : 1237 被引量:1
  • 5ISO. in vitro diagnostic medical devices measurement of quantities in samples of biological origin - metrological traceability of values assigned to calibrators and control materials. ISO/DIS 17511, Geneva, 2000 被引量:1
  • 6ISO. in vitro diagnostic medical devices measurement of quantities in samples of biological origin metrological traceability of values for catalytic concentration of enzymes assigned to calibrators and control materials. ISO/DIS 18153, Geneva,2000 被引量:1
  • 7ISO. General requirements for the competence of testing and calibration laboratories. ISO/IEC 17025, Geneva, 1999 被引量:1
  • 8ISO. Quality management in the medical laboratory. ISO/FDIS 15189, Geneva, 2000 被引量:1
  • 9IFCC. IFCC primary reference procedures for the Measurement of catalytic activity concentrations of enzymes at 37 C. Clin Chem Lab Med 2002,40(6) :631 被引量:1
  • 10NCCLS. H15 - A3 Reference and Selected Procedures for the Quantitative Determination of Hemoglobin in Blood. Approved Standard. 3rd Edition, 2000 被引量:1

引证文献2

二级引证文献12