摘要 本文通过设定简化建筑模型,采用PHPP软件测算建筑采暖能耗,对合理设置建筑朝向、窗墙比以及围护结构性能优化等被动式措施的综合作用对建筑采暖能耗的影响进行了分析,得出了相关结论;为建筑师在建筑设计过程中,对建筑朝向、窗墙比和围护结构性能等因素进行综合考虑提供参考。 This paper analyzes the influence of the combined effects of passive energy-efficient measures,such as the optimization of building orientation,area ratio of window to wall,and building envelope performance,on heating energy consumption,by setting a simplified building model and using PHPP to calculate the heating energy consumption.It provides guidance for architects to take overall consideration of factors such as building orientation,area ratio of window to wall,and building envelope performance,in the design process.
出处 《动感(生态城市与绿色建筑)》 2011年第1期56-59,共4页 Eco-city and Green Building
基金 国家国际科技合作计划资助 项目编号:2010DFA74490
关键词 采暖 外围护结构 建筑朝向 窗墙比 Heating,Building Envelope,Building Orientation,Area Ratio of Window to Wall
  • 相关文献

参考文献3

二级参考文献7

  • 1李兆坚,江亿.北京市住宅空调负荷和能耗特性研究[J].暖通空调,2006,36(8):1-6. 被引量:27
  • 2王远,魏庆冗,薛志峰,江亿.北京市大型公共建筑能耗统计数据库与初步分析.暖通空调年会文章,2006 被引量:1
  • 3中国统计年鉴[G].北京:中国统计出版社,2006. 被引量:1
  • 4中国建筑节能年度发展研究报告[R].北京:中国建筑工业出版社,2007. 被引量:2
  • 5Hiroshi YOSHINO. Current Status of Energy Use and Low GHG emission Strategies for Residential Buildings in Japan and China[J]. Journal of Harbin Institute of Technology 被引量:1
  • 6International Energy Outlook 2006, Energy International Administration 被引量:1
  • 7Handbook of Energy & Economic Statistics in Japan. 被引量:1

共引文献46