开绕组永磁同步发电机的容错控制 被引量:17

Fault-Tolerant Control Technique of Permanent Magnet Synchronous Generator Based on Open Winding Configuration
下载PDF
导出
摘要 为实现开绕组永磁同步发电机(PMSG)在变流器故障下的容错运行,本文通过分析开绕组PMSG系统变流器存在的故障类型,建立容错故障状态下开绕组PMSG的数学模型,通过研究不同故障状态下两个变流器的电压矢量分布,给出了开绕组PMSG变流器容错运行所需的电压空间矢量分配机制,进而提出每种故障状态下的开绕组PMSG控制策略。最后通过搭建的开绕组永磁电机实验平台,验证了所提出容错运行方案的可行性。 In order to implement the fault-tolerant operation of converter for permanent magnet synchronous generator(PMSG) based on open winding configuration,the paper firstly analyzed the fault types of the converter,and developed the mathematic model of open winding PMSG under the fault tolerant operation condition.Then,by investigating the voltage vector distribution of two generator side converters on the different fault condition,the synthetic voltage vector assignment mechanism and control strategy of the converter fault tolerant operation for open winding PMSG is proposed.Finally,the experimental system of the open winding PMSG is built to validate the availability of the proposed fault-tolerant operation strategy.
出处 《电工技术学报》 EI CSCD 北大核心 2015年第10期58-67,共10页 Transactions of China Electrotechnical Society
关键词 开绕组永磁同步发电机 变流器故障 容错运行 电压空间矢量分配机制 Open winding permanent magnet synchronous generator converter fault fault tolerant operation voltage space vector assignment mechanism
  • 相关文献

参考文献9

  • 1Jamal A. Baroudi,Venkata Dinavahi,Andrew M. Knight.A review of power converter topologies for wind generators[J]. Renewable Energy . 2007 (14) 被引量:1
  • 2Chen, Zhe,Guerrero, Josep M.,Blaabjerg, Frede.A review of the state of the art of power electronics for wind turbines. IEEE Transactions on Power Electronics . 2009 被引量:1
  • 3Carrasco JM,Franquelo LG,Bialasiewicz JT,et al.Power-Electronic systems for the grid integration of renewable energy sources: a survey. IEEE Transactions on Industrial Electronics . 2006 被引量:1
  • 4Jose A. Restrepo,Alberto Berzoy,Antonio E. Ginart.Switching Strategies for Fault Tolerant Operation of Single DC-link Dual Converters. IEEE Transactions on Power Electronics . 2012 被引量:1
  • 5Jae Hyeong Seo,Chang Ho Choi,Dong Seok Hyun.A new simplified space-vector PWM method for three-level inverters. IEEE Transactions on Power Electronics . 2001 被引量:2
  • 6Hwang J-C,Wei H-T.The current harmonics elimination control strategy for six-legthree-phase permanent magnet synchronous motor drives. IEEE Transactions onPower Electronics . 2014 被引量:1
  • 7Azeez N A,Gopakumar K,Mathew J.A harmonic suppression scheme for open end winding split phase IM drive using capacitive filters for the full speed range. IEEE Transactions on Industry Applications . 2014 被引量:1
  • 8Roshan Kumar P,Rajeevan P P,Mathew K.A three level common mode voltage eliminated inverter with single DC supply using flying capacitor inverter and cascaded H-bridge. IEEE Transactions on Power Electronics . 2014 被引量:1
  • 9Zhou Yijie,Nian Heng.Sensorless control of PMSG based on dual two-level inverter open winding configuration for wind turbines. 15th International Conference on Electrical Machines and Systems(ICEMS2012) . 2012 被引量:1