摘要
针对镇海电厂锅炉低负荷稳燃能力差、炉膛出口烟温偏差大等问题,通过理论和实验研究,提出燃烧器工程技术改造方案,并在现场实施。运行测试表明,此方案切实可行,改造效果很好。
Theoretical and experimental study is conducted to solve boiler low-load steady combustion and great gas temperature windage. The technical retrofit of burner is put forward and put into use at site. Operation and test show that this project is practical and feasible, the retrofit results are good.
出处
《电站系统工程》
北大核心
2002年第5期5-7,共3页
Power System Engineering
关键词
锅炉
低负荷稳燃
烟温偏差
燃烧器
技术改造
bias combustion
low-load steady combustion
gas temperature windage
burner retrofit