摘要
基于目前常用的光谱杂散光测试与修正方法,详细介绍了光谱杂散光矩阵修正法的核心内容——仪器的光谱杂散光矩阵的标定。在实验室搭建了杂散光矩阵测量装置,标定了前向临边成像光谱仪初样机的杂散光矩阵,在外场实验中验证了基于仪器杂散光矩阵的杂散光修正方法的精度。
Based on a brief introduction to the current methods of stray light testing and correction, the spectral stray light matrix calibration, which is the core content of the spectral stray light matrix correction method, is introduced in detail in this paper. Then, to calibrate the stray light matrix of the prototype of the forward limb imaging spectrometer, we set up a stray light matrix measuring device in the laboratory. Finally, the accuracy of the stray light correction method based on the stray light matrix of the instrument is verified in an external field experiment.
作者
李占峰
王淑荣
黄煜
薛庆生
Li Zhanfeng;Wang Shurong;Huang Yu;Xue Qingsheng(State Key Laboratory of Applied Optics,Changchun Institute of Optics,Fine Mechanics and Physics,Chinese Academy of Sciences,Changchun,Jilin 130033,China)
出处
《光学学报》
EI
CAS
CSCD
北大核心
2018年第11期1-5,共5页
Acta Optica Sinica
基金
国家自然科学基金(41575023)
国家重点研发计划(2016YFB0500300
2016YFB0500301
2016YFB0500302
2016YFB0500303
2016YFB0500304)
关键词
大气光学
杂散光修正
杂散光矩阵
光谱杂散光
成像光谱仪
遥感定量化
atmospheric optics
stray light correction
stray light matrix
spectral stray light
imaging spectrometer
remote sensing quantification