期刊文献+

Posterior chamber phakic intraocular lens for the correction of high myopic anisometropic amblyopia in adults 被引量:3

Posterior chamber phakic intraocular lens for the correction of high myopic anisometropic amblyopia in adults
下载PDF
导出
摘要 This study aims to evaluate the clinical results of posterior chamber implantable collamer lens(ICL) implantation in adults with high myopic anisometropic amblyopia. Thirteen patients aged 27.04±7.24 y(range 19.2 to 42.5) were studied. ICL implantation was performed in 13 amblyopic eyes. The mean myopic anisometropia was significantly dropped from-10.70±3.02 D preoperatively to +0.09±1.67 D at 1 mo postoperatively. The logMAR CDVA at 3 d, 1, 3 and mean 9 mo postoperatively improved by a mean of 1.69, 2.50, 3.01 and 3.00 lines and gained more than 2 lines accounted for 23.08%(3 eyes), 41.67%(5 eyes), 63.63%(7 eyes) and 55.56%(5 eyes), respectively. The contrast sensitivity of amblyopic eyes was significantly increased after surgery. Four patients partially recovered near stereopsis(400" to 100"). There was no severe complications were observed. ICL implantation alone can improve vision, contrast sensitivity, and partial restoration of binocular vision in adult patients with high myopic anisometropia. This study aims to evaluate the clinical results of posterior chamber implantable collamer lens(ICL) implantation in adults with high myopic anisometropic amblyopia. Thirteen patients aged 27.04±7.24 y(range 19.2 to 42.5) were studied. ICL implantation was performed in 13 amblyopic eyes. The mean myopic anisometropia was significantly dropped from-10.70±3.02 D preoperatively to +0.09±1.67 D at 1 mo postoperatively. The logMAR CDVA at 3 d, 1, 3 and mean 9 mo postoperatively improved by a mean of 1.69, 2.50, 3.01 and 3.00 lines and gained more than 2 lines accounted for 23.08%(3 eyes), 41.67%(5 eyes), 63.63%(7 eyes) and 55.56%(5 eyes), respectively. The contrast sensitivity of amblyopic eyes was significantly increased after surgery. Four patients partially recovered near stereopsis(400" to 100"). There was no severe complications were observed. ICL implantation alone can improve vision, contrast sensitivity, and partial restoration of binocular vision in adult patients with high myopic anisometropia.
出处 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第11期1870-1874,共5页 国际眼科杂志(英文版)
基金 Supported by Natural Science Foundation of China (No.81670848 No.81470626)
关键词 phakic intraocular lens myopic anisometropic AMBLYOPIA refractive surgery phakic intraocular lens myopic anisometropic amblyopia refractive surgery
  • 相关文献

同被引文献19

二级引证文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部