摘要
分析了空调冷凝水的产生与现状,根据卡诺循环,将空调冷凝水量进行了理论计算,分析冷凝水回收对降低夏季空调运行能耗的影响。提出如何高效地回收利用空调冷凝水,降低空调运行能耗,达到节能减排的目的,并与传统冷凝水回收方案进行对比分析。
This paper analyzes the generation and present situation of condensate in air-conditioning system, calculates the condensate quantity of air-conditioning system according to Carnot cycle, and analyzes the influence of condensate recovery on reducing energy consumption of air-conditioning system in summer. This paper puts forward how to recycle the condensate of air conditioning efficiently, reduce the energy consumption of air conditioning operation, and achieve the purpose of energy saving and emission reduction.
作者
李娴
杨柳
王爱平
王庆港
杨凯
韩滔
Li Xian;Yang Liu;Wang Ai-ping;Wang Qing-gang;Yang Kai;Han Tao
基金
西南石油大学开放性实验重点研究项目
西南石油大学亚大基金研究项目
四川省创新创业培训计划
关键词
空调
冷凝水
再利用
节能
air conditioning
condensate water
reuse
energy saving