期刊文献+

航空发动机火警检测及告警系统可靠性设计 被引量:1

Reliability Design of Aero-engine Fire Detection and Alarm System
下载PDF
导出
摘要 目前航空发动机火警检测及告警系统经常出现"有警不报"和"无警虚报"两种故障模式。介绍了火警检测及告警系统的组成部分及各部分的功能,分析了传统的火警检测及告警系统可靠性低的原因,针对该问题,提出了系统的优化设计理论,包括BIT设计、硬滤波设计、余度设计、软滤波设计及迟滞比较设计,并对每种设计的实现方法进行了详细阐述。根据"可靠度"参数的计算结果,优化设计的火警检测及告警系统的任务可靠性相比传统的火警检测及告警系统得到了极大的提升。 At present,aero engine fire detection and alarm systems often have two failure modes: no fire alarm when there is fire,or fire alarm when there is no fire.This article describes the fire detection and alarm system components and functions of each part.The reason of low reliability of traditional fire detection and alarm system is analyzed.In view of this problem,the optimal design theory of the system is proposed,including BIT design,hardware filter design,redundancy design,software filter design and hysteresis comparison design.The implementation of each design is described in detail.According to the calculation results of the “reliability” parameter,the fire detection and alarm system’s mission reliability optimized has been greatly improved compared with the traditional fire detection and alarm system.
作者 郭建奇 杨东亮 张宇坤 王建生 GUO Jian qi;YANG Dong liang;ZHANG Yu kun;WANG Jian sheng(Xi′an Aeronautics Computing Technique Research Institute,AVIC,Xi′an 710068,China)
出处 《航空计算技术》 2018年第5期225-228,共4页 Aeronautical Computing Technique
基金 航空科学基金项目资助(2016ZC31004)
关键词 火警检测及告警系统 机内自测试 双余度 迟滞比较 可靠度 fire detection and alarm system BIT design dual redundancy design hysteresis comparison reliability
  • 相关文献

参考文献6

二级参考文献17

共引文献24

同被引文献2

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;