期刊文献+

Activation reduction following an eccentric contraction impairs torque steadiness in the isometric steady-state 被引量:3

Activation reduction following an eccentric contraction impairs torque steadiness in the isometric steady-state
下载PDF
导出
摘要 Background:The isometric steady-state following active lengthening is associated with greater torque production and lower activation,as measured by electromyographic activity(EMG),in comparison with a purely isometric contraction(ISO)at the same joint angle.This phenomenon is termed residual force enhancement(RFE).While there has been a great deal of research investigating the basic mechanisms of RFE,little work has been performed to understand the everyday relevance of RFE.The purpose of this study was to investigate whether neuromuscular control strategies differ between ISO and RFE by measuring torque steadiness of the human ankle plantar flexors.Methods:Following ISO maximal voluntary contractions in 12 males(25±4 years),an active lengthening contraction was performed at 15°/s over a 30°ankle excursion,ending at the same joint angle as ISO(5°dorsiflexion;RFE).Surface EMG of the tibialis anterior and soleus muscles was recorded during all tasks.Torque steadiness was determined as the standard deviation(SD)and coefficient of variation(CV)of the torque trace in the ISO and RFE condition during activation-matching(20%and 60%integrated EMG)and torque-matching(20%and 60%maximal voluntary contraction)experiments.Two-tailed,paired t tests were used,within subjects,to determine the presence of RFE/activation reduction(AR)and whether there was a difference in torque steadiness between ISO and RFE conditions.Results:During the maximal and submaximal conditions,there was 5%-9%RFE with a 9%-11%AR(p<0.05),respectively,with no difference in antagonist coactivation between RFE and ISO(p>0.05).There were no differences in SD and CV of the torque trace for the 20%and60%activation-matching or the 60%and maximal torque-matching trials in either the RFE or ISO condition(p>0.05).During the 20%torquematching trial,there were~37%higher values for SD and CV in the RFE as compared with the ISO condition(p<0.05).A significant moderate-to-strong negative relationship was identified between the reduction in torque steadiness follow Background:The isometric steady-state following active lengthening is associated with greater torque production and lower activation,as measured by electromyographic activity(EMG),in comparison with a purely isometric contraction(ISO)at the same joint angle.This phenomenon is termed residual force enhancement(RFE).While there has been a great deal of research investigating the basic mechanisms of RFE,little work has been performed to understand the everyday relevance of RFE.The purpose of this study was to investigate whether neuromuscular control strategies differ between ISO and RFE by measuring torque steadiness of the human ankle plantar flexors.Methods:Following ISO maximal voluntary contractions in 12 males(25±4 years),an active lengthening contraction was performed at 15°/s over a 30°ankle excursion,ending at the same joint angle as ISO(5°dorsiflexion;RFE).Surface EMG of the tibialis anterior and soleus muscles was recorded during all tasks.Torque steadiness was determined as the standard deviation(SD)and coefficient of variation(CV)of the torque trace in the ISO and RFE condition during activation-matching(20%and 60%integrated EMG)and torque-matching(20%and 60%maximal voluntary contraction)experiments.Two-tailed,paired t tests were used,within subjects,to determine the presence of RFE/activation reduction(AR)and whether there was a difference in torque steadiness between ISO and RFE conditions.Results:During the maximal and submaximal conditions,there was 5%-9%RFE with a 9%-11%AR(p<0.05),respectively,with no difference in antagonist coactivation between RFE and ISO(p>0.05).There were no differences in SD and CV of the torque trace for the 20%and60%activation-matching or the 60%and maximal torque-matching trials in either the RFE or ISO condition(p>0.05).During the 20%torquematching trial,there were~37%higher values for SD and CV in the RFE as compared with the ISO condition(p<0.05).A significant moderate-to-strong negative relationship was identified between the reduction in torque steadiness follow
出处 《Journal of Sport and Health Science》 SCIE 2018年第3期310-317,共8页 运动与健康科学(英文)
基金 supported by the Natural Sciences and Engineering Research Council of Canada
关键词 ECCENTRIC FORCE STEADINESS History dependence Residual FORCE enhancement TREMOR Eccentric Force steadiness History dependence Residual force enhancement Tremor
  • 相关文献

同被引文献5

引证文献3

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部