利用蒙特卡洛法分析数据中心典型供配电架构的系统可用性 被引量:2

Availability Analysis of Typical Power Distribution Architecture in Data Center Based on Monte Carlo Method
下载PDF
导出
摘要 基于4种数据中心典型供配电架构系统,应用蒙特卡洛法进行了定量的研究和分析,得出4种架构可用性的差别,并详细给出了计算步骤。通过介绍有效地说明了蒙特卡洛法在计算复杂供配电系统可用性上的先进性和实用性,从而在设计初期能够实现数据中心供配电系统的优化。 Based on the four typical data center power distribution architectures, this paper used Monte Carlo method to do the quantitative research and analysis. It comes to the difference between the four architectures' availability,detailed gives the calculation step. The paper illustrates the advancedness and effectiveness of using Monte Carlo method to calculate the complex power distribution system availability ,which can implement the power distribution optimization at the beginning of the design of the data center.
作者 徐磊 XU Lei(China)Co.,Ltd.,Shanghai 201203,China])
出处 《电器与能效管理技术》 2018年第17期54-57,共4页 Electrical & Energy Management Technology
关键词 数据中心 供配电 可用性 典型架构 模型仿真 data center power distribution availability typical architecture model simulation