电絮凝—MCBR微型回旋生物反应组合处理荧光废水 被引量:3

Treatment of Fluorescent Penetrant Wastewater by Electric Flocculatio-MCBR Micro-cyclotron Bioreactor Combination
下载PDF
导出
摘要 为解决零件制造厂中作金属探伤使用过的荧光渗透剂废水含多项污染指标(如COD、TN、SS、5-羟基荧光素琥珀亚胺酯、色度等)、成分复杂、难降解、单一生化法达不到排放标准的问题,采用电絮凝氧化装置—MCBR(微型回旋生物反应池)—离心分离组合工艺技术,荧光渗透剂废水经过一系列净化流程后,水质达到GB 3838—2002《城镇污水处理厂污染物排放标准》中一级标准的A类标准。 Fluorescent penetrant wastewater used for metal flaw detection in parts manufacturing plants contains multiple pollution indicators, such as COD, TN, SS,5-hydroxyl, fluorescein, color etc. The composition of wastewater is complex and it is difficult to degrade. Treatment with single biochemical method does not meet the emission standard. However, it can be treated with electric flocculation oxidation device-MCBR (Mini cyclotron biological reactor)-Centrifugal separation and combination technology. After a series of purification process, the quality of the treated water reaches the class A standard of the first class standard for the discharge standard of pollutants in the urban sewage treatment plant (GB 3838 2002).
作者 庞滔 唐建城 吴菊珍 景江 李强林 PANG Tao;TANG Jiancheng;WU Juzhen;JING Jiang;LI Qianglin(Institute of Architectural and Environmental Engineering,Chengdu Technological University,Chengdu 611730,China)
出处 《成都工业学院学报》 2018年第3期37-40,共4页 Journal of Chengdu Technological University
基金 四川省教育厅项目(18ZA0024)
关键词 荧光渗透剂 电絮凝 MCBR微生物催化氧化 组合工艺 fluorescent penetrant electric flocculation MCBR Microbial catalytic oxidation combination technology