摘要 针对现在石油化工装置布置紧凑、设计周期短等要求,标准节流式差压流量计直管段要求无法得到满足的问题非常突出。以孔板为例,比较分析了几种常用节流式差压流量计的结构、精度,着重分析对安装直管段的要求,从而提出了在紧凑型化工装置中较适宜的流量计选型。 With respect to some requirements existed in petrochemical industry, such as compact structure and short period in design, the problem that standard differential pressure flow-meter cannot reach these requirements is prominent. In this article, exampled with orifice plate, several commonly used orifice differential pressure flow-meters were analyzed and compared in stricture and precision, and the requirement for installation of straight segment was emphatically analyzed, so that the appropriate flow-meter used in compact chemical construction was presented.
作者 林晓毅 Lin Xiaoyi(SINOPEC Shanghai Engineering Co.,Ltd,Shanghai 200120)
出处 《化工与医药工程》 2018年第4期50-53,共4页 Chemical and Pharmaceutical Engineering
关键词 紧凑型 直管段要求 标准孔板 多孔孔板流量计 平衡流量计 compact style requirement for straight segment standard orifice plate multi-hole orifice flow meter balanced flow meter
  • 相关文献

参考文献2

二级参考文献28

  • 1朱云.脉动流对差压式流量计测量误差影响的研究[J].仪器仪表学报,2006,27(8):894-897. 被引量:14
  • 2PETERS R J W,HODGES C, et al. Testing the waferV-cone flowmeters in accordance with API 22 “testingprotocol” section 2-“ differential pressure flow measure-ment devices” in the CEESI Colorado test facility [ C ].6th International Symposium on Fluid Flow Measure-ment ,2006. 被引量:1
  • 3PETERS R J W,STEVEN R,CALDWELL S,et al. Testingthe wafer V-cone flowmeters in accordance with API 5. 7“testing protocol for differential pressure flow measurementdevices” in the CEESI Colorado test facility [ J ]. Flow Meas-urement and Instrumentation ,2006,17 (4) :247-254. 被引量:1
  • 4SINGH S N,SESHADRI V,SINGH R K,et al. Effect ofupstream flow disturbances on the performance character-istics of a V-cone flowmeter [ J ] . Flow Measurement andInstrumentation,2006,17(5) :291 -297. 被引量:1
  • 5International standard ISO 5167-2 2nd edition. Measurementof fluid flow by means of pressure differential devices insert-ed in circular cross-section conduits running full-part 1:General Principles and requirements [ S ]. 2003. 被引量:1
  • 6International standard ISO 5167-2 2nd edition. Measure-ment of fluid flow by means of pressure differential de-vices inserted in circular cross-section conduits runningfull-part 2 : Orifice plates [ S]. 2003. 被引量:1
  • 7Geng Yanfeng, Zheng Jinwu, Shi Tianming. Study on the metering characteristics of a slotted orifice for wet gas flow [J]. Flow Measurement and Instrumentation, 2006, 17 (2) : 123-128. 被引量:1
  • 8付贵生.美国石油协会(API)及其主要标准类目简介[J].安全、环境、健康,2001,1(16):5. 被引量:1
  • 9Peter Dr R J W, Hodges Casey. Testing the vafer V-Cone flowmeters in accordance with API 22 "testing protocol" sec- tion 2 differential pressure flow measurement devices" in the CEESI colorado test facility[C]//6^th International Symposi- um on Fluid Flow Measurement. Queretaro, Mexico- CEESI Colorado Test Facility, 2006:3-4. 被引量:1
  • 10Singh S N, Seshadri V, Singh R K,et al. Effect of upstream flow disturbances on the performance characteristics of a V cone flowmeter[J]. Flow Measurement and Instrumenta- tion,2006,17(5) :219-217. 被引量:1