摘要
汽提塔是高压系统重要的设备之一,汽提塔的腐蚀直接影响装置的长期平稳运行。本文针对近年来汽提塔的腐蚀案例进行总结和分析,并从设备和工艺两方面提出可行性建议,为装置长满优运行提供了相应的保证。
Stripper is one of the important equipment in high pressure system. Corrosion of stripper directly affects the long-term stable operation of the unit. This paper summarizes and analyzes stripper corrosion cases in recent years, proposes feasibility suggestions from aspects of equipment and process, provides corresponding guarantees for safe, stable, long-term, full capacity and high quality operation of the unit.
作者
姬广发
粟升
宋程
闫泽强
李江威
李希望
JI Guang-fa;SU Sheng;SONG Cheng;YAN Ze-qiang;LI Jiang-wei;LI Xi-wang(Tarim Oilfield Petrochemical Branch Company,Korla 841000,Xinjiang Province)
出处
《氮肥技术》
2018年第3期30-32,共3页
Nitrogenous Fertilizer Technology
关键词
汽提塔
腐蚀
泄漏
原因
建议
stripper
corrosion
leakage
cause
suggestion