期刊文献+

CT能谱成像基本原理及降低辐射剂量新技术 被引量:11

The principle of CT spectral imaging and current progress in reducing radiation dose
下载PDF
导出
摘要 CT能谱成像作为一种全新的成像模式,不但成为业内研究的热点,而且已广泛用于全身各系统病变的诊断,其在降低CT辐射剂量方面的价值也得到了一定的认可。本文就CT能谱成像设备组成、成像原理、图像特点和在降低辐射剂量方面的价值及新进展进行初步的总结、介绍。 CT spectral imaging is a new imaging modality,which has not only become the focus in imaging research,but also has been widely used in the diagnosis of variable diseases. At the same time,the efforts of reducing radiation dose in CT imaging has widely been made. In this paper,we try to make a preliminary summary and introduction to the composition of CT energy spectrum imaging equipment,imaging principles,imaging characteristics,the reduction of the radiation dose and its new progress.
作者 郭浩 巴新茹 刘奉立 公佩友 GUO Hao;BA Xinru;LIU Fengli;GONG Peiyou(The Radiology Department of Yantai Yuhuangding Hospital,Yantai 264000,P.R.China;The Radiology Department of Yantaishan Hospital,Yantai 264000,P.R.China)
出处 《医学影像学杂志》 2018年第8期1394-1397,共4页 Journal of Medical Imaging
基金 山东省自然科学基金(编号:ZR2017LH053)
关键词 体层摄影术 X线计算机 能谱成像 成像原理 辐射剂量 迭代技术 Tomogarphy X-ray computed Spectral imaging Imaging principles Radiation dose herative algorithm
  • 相关文献

参考文献8

二级参考文献105

  • 1高建华,孙宪昶,李剑颖,王贵生,李娜,戴汝平.后置滤过器C_2对64层螺旋CT冠状动脉成像质量的影响[J].中国医学影像技术,2007,23(1):73-76. 被引量:31
  • 2Brenner DJ, Hall EJ. Computed tomography an increasing source of radiation exposure. N Eng J Med, 2007,357(22) :2277- 2284. 被引量:1
  • 3Gunn ML, Kohr JR. State of the art: Technologies for computed tomography dose reduction. Emerg Radiol, 2009, 17 (3) : 209- 218. 被引量:1
  • 4Ulzheimer S, Endt H, Flohr T. Computed tomography-patientdose and dose reduction technologies. Health Phys, 2011, 100 (3) :325-328. 被引量:1
  • 5Silva AC, Lawder HJ, Hara A, et al. Innovations in CT dose re- duction strategy: Application of the adaptive statistical iterative reconstruction alglrithm. AIR Am J Roentgenol, 2010, ]94(1): 191-199. 被引量:1
  • 6Mi6ville FA, Gudinchet F, Brunelle F, et al. Iterative recon- struction methods in two different MDCT scanners: Physical met- rics and 4-alternative forced-choice detectability experiments--A phantom approach. Physica Mediea, 2012, Jan 2. [Epub ahead of print]. 被引量:1
  • 7Launders J. Radiation risks: CT dose-reduction technologies: A review. Biomed Instrum Technol, 2011,45(6):453-457. 被引量:1
  • 8Schueller-Weidekamm C, Schaefer-Prokop CM, Weber M, et al. CT angiography of pulmonary arteries to detect pulmonary embol- ism: Improvement of vascular enhancement which low kilovoltage settings. Radiology, 2006,241(3) : 899-907. 被引量:1
  • 9Nakayama Y, Awai K, Funama Y, et al. Lower tube voltage re-duces contrast material and radiation dose on 16-MDCT aortogra- phy. AJR Am J Roentgenol, 2006,187(5) :W490-497. 被引量:1
  • 10Katsura M, Matsuda I, Akahane M, et al. Model-based itera- tire reconstruction technique for radiation dose reduction in chest CT: Comparison with the adaptive statistical iterative recon- struction technique. Eur Radiol, 2012,22(8) : 1613-1623. 被引量:1