期刊文献+

山地机场雷电灾害风险分析与防护——以贵阳龙洞堡机场为例 被引量:6

Risk Analysis and Protection of Lightning Disaster in Mountainous Airport——Take Guiyang Longdongbao Airport as an Example
下载PDF
导出
摘要 机场遭受雷击的事故时有发生,严重影响航空安全,因此机场的雷电防护十分重要。该文以贵阳龙洞堡机场为例,采用接地与电磁分析软件,分析了机场的雷电环境、土壤泄流性能以及雷电灾害风险,并基于此提出机场的雷电灾害防护重点,为减少或避免机场的雷电灾害风险,科学指导机场的防雷设计具有一定的指导意义。 The airport was struck by lightning occasionally,which seriously affected the safety of aviation. The importance of lightning protection goes without saying. Taking Guiyang Longdongbao Airport as an example,we analyzed the lightning environment,soil discharge performance and lightning disaster risk of the airport by using grounding and electromagnetic analysis software. Lightning protection focus was proposed to reduce or avoid the risk of lightning disaster. Scientific guidance has certain instructional significance to lightning protection design of airport.
作者 李连伟 刘波 LI Lianwei;LIU Bo(Guizhou Branch of Air Traffic Management Bureau in Southwest China,Guiyang 550002,China;Guizhou Meteorological Disaster Defense Technology Center,Guiyang 550081,China)
出处 《中低纬山地气象》 2018年第2期68-71,共4页 Mid-low Latitude Mountain Meteorology
关键词 机场 雷电灾害风险 防雷重点 airport lightning hazard risk lightning protection focus