摘要
通过现场测试手段,对建筑内外进行实际测量,分析宿舍楼的声环境、光环境以及热环境等物理环境指标。重点从声强度、光照强度、温湿度、风速、表面温度、热舒适性等角度研究宿舍楼物理环境状况。研究结果表明,声环境和光环境需要局部优化处理,热环境指标最差,需要重点关注处理。
Through on-site testing, we conducted the actual measurement inside and outside the building and analyzed the physical environment indicators such as acoustic environment, light environment and thermal environment of the dormitory building. The focus includes the researches on the physical environment of the dormitory from the aspects of acoustic intensity, light intensity, temperature and humidity, wind speed, surface temperature and thermal comfort. The research results show that the acoustic environment and the light environment need local optimization, and the thermal environment index is the worst, which needs to be paid attention and handled.
作者
张军学
张一波
逯航
ZHANG Junxue;ZHANG Yibo;LU Hang
出处
《住宅科技》
2018年第8期49-54,共6页
Housing Science
关键词
夏热冬冷地区
超大玻璃幕墙
声环境
光环境
热环境
hot summer and cold winter area
oversized glass curtain wall
acoustic environment
light environment
thermal environment